General System Description and Installation
1-45
General System De
script
ion and Installation
1
protected by a dedicated circuit breaker.
Do not
connect ancillary equipment to the
same facilities power outlet as the Coral IPx system.
Connecting the AC Cage Connection to the Power Connection
1.
Connect an AC power cord through the opening in the top section of the unit to
the AC power receptacle.
2.
Connect the other end of the cord either to the facilities power socket or to the
power strip.
Electrical Fire Hazard. Verify that no more than up to three cages of the Coral IPx 500
system are connected to the same circuit breaker (rating: 6A C, 10 kA breaking
capacity). Doing so could result in currents that exceed the allowable limit and cause a
fire. Connect ancillary equipment to a different power outlet that is protected by a
different circuit breaker.
Electrical Hazard. Verify that the AC power strip or outlet supplying the cage is easily
accessible and can be easily disconnected in the event of emergency. Verify that that
the power strip or outlet is no higher than 63" (160 cm) from the floor.