background image

M038010E 

 

Troubleshooting Guide      

                                        23                                         

Troubleshooting Guide

 

Troubleshooting Guide 

 
First check the following when a problem occurs during the radio-control operation. 

 

Trouble

 

Checkpoints

 

Measures

 

Power LED does not 
light up. 

 

・ 

Are batteries inserted? 

・ 

Are batteries inserted in the 

 correct manner? 

・ 

Are batteries exhausted?

 

・ 

Insert batteries. 

・ 

Insert batteries in the 

 correct manner. 

・ 

Replace batteries.

 

Power LED flashes.

 

・ 

Are batteries exhausted?

 

・ 

Replace batteries

 

After the power is 
turned on, four LEDs 
flash. 

 

・ 

Was the power turned on while 

 the switch on the transmitter 
 was  operated? 

・ 

Was the power turned on while 

  the speed control lever was 
 pulled? 

 

・ 

After releasing your finger 

  from the switch, turn on 
 the power. 

・ 

After releasing your finger 

 from the speed control 
 lever, turn on the power. 

 

The power of the 
transmitter 
spontaneously turned 
off.  

 

・ 

When no operation is made for 

  approximately one hour, the 
  power of the transmitter is 
  automatically turned off to save 
 battery consumption. 

・ 

Turn on the power again. 

The power is turned off 
during the radio-control 
operation. 

 

・ 

When the motion selection 

  switch is under operational 
  state continuously for 
  approximately five minutes, 
  transmission from the 
  transmitter is automatically cut 
  off to prevent accidents. 

・ 

After confirming that the 

  motion selection switches 
  are retuned to the neutral 
  positions, turn on the 
 power again. 

 

The accelerator cannot 
be revved up. 
 

・ 

Is the low-speed mode (with 

  the speed mode LED lighting in 
 red) selected?  

・ 

Change to the 

 medium-speed or 
 high-speed mode. 

 

Batteries are 
exhausted in a short 
time 
 

・ 

Battery longevity is shortened 

  under the conditions with 
 extremely cold temperatures. 

・ 

Replace batteries. 

 

The crane stops with 
two-tone sound. 
 

・ 

Are cables of the reception unit 

  or control unit loose?   

・ 

Is the crane used in the 

  situation as shown on the next 
 page? 

・ 

Connect the cable 

 properly. 

・ 

Refer to the next page. 

 

 

 

Summary of Contents for RCS-FC1

Page 1: ...on 9 4 Instant Stop Alarm Function 9 5 Alarm Function 10 Radio control 11 1 Preparation for Radio control Operation 11 2 How to Operate the Radio control 13 3 Changing Speed Mode 15 4 Engine Start up...

Page 2: ...l system with the nameplates shown in the following illustrations Illustrations in this manual may differ from the actual products in details Note that the illustrations for explanation purposes are s...

Page 3: ...ol System 3 Configurations of Radio control System Configurations of Radio control System M22656E Control unit Communication unit Speaker for alarm Emergency stop lamp Radio control valve Transmitter...

Page 4: ...p switch 1 Engine start LED Red Green 2 Speed mode LED Red Green 6 Elevation selection switch 9 Swing selection switch 7 Hook selection switch 8 Extension selection switch 16 Speed control lever 18 Co...

Page 5: ...off turned on in red 6 Elevation Selection Switch 7 Hook Selection Switch 8 Extension Selection Switch 9 Swing Selection Switch These are the motion selection switches for the crane operation When th...

Page 6: ...on while the radio control manual changeover switch of the crane is turned to the Radio position after PTO is set to Engaged state the lamp also lights up once 20 Communication Unit LED The LED shows...

Page 7: ...io control Manual Changeover Switch This is the switch to select radio control operation manual operation Radio Radio control operation Manual Manual operation 3 Emergency Stop Lamp The LED shows the...

Page 8: ...gain to turn on the power LED to set to the radio control mode 2 Switch Failure Detection Function Error is displayed when the power of the transmitter is turned on while the switches or speed control...

Page 9: ...r lamp of the control unit changes to L0 To resume the radio control operation turn the power on once again after confirming the position of the motion selection switches 4 Instant Stop Alarm Function...

Page 10: ...Crane operation The radio control operation is disabled Measure Refer to the chapter of Measures for Emergency Case 3 Battery exhaustion warning Warning sound Two tone alarm once Warning timing When t...

Page 11: ...ure according to the PTO operation operation of the radio control manual changeover switch and power ON OFF of the radio control transmitter In addition an indication on the mode indicator lamp of the...

Page 12: ...n the switch failure detection function works to indicate the error state Refer to the chapter of Safety Functions of Radio control System Do not touch any other switch or lever than the power switch...

Page 13: ...normally by making the following operations Extending and retracting of the boom raising and lowering of the boom hoisting up and down the hook and turning of the hook It is dangerous to rapidly pull...

Page 14: ...increases according to the amount the lever is pulled Adjust the moving speed of the crane with the speed control lever 3 To call the attention of the surrounding people during the operation press th...

Page 15: ...vention is necessary during nighttime operation and the like The speed mode is memorized even after the power is turned off Next time the power of the transmitter is turned on the previously selected...

Page 16: ...icate the emergency stop state Beep alarm sounds How to Release Emergency Stop Press the switch once again Then the emergency stop LED and emergency stop lamp of the crane turn off and the emergency s...

Page 17: ...s out of reach the control unit still appears to be on in the radio control mode Make sure to confirm that the mode indicator lamp of the control unit indicates L0 after the radio control operation is...

Page 18: ...NOTE Inserting the batteries incorrectly for plus and minus may cause a liquid spill ignition heat generation and burst Insert the batteries according to the direction plate If the battery cover is lo...

Page 19: ...s shown in the table are displayed In either case once again turn the power on If the power of the transmitter is turned on while the push switch the horn engine start and speed mode is operated indic...

Page 20: ...r Trouble and measure 13 After releasing your fingers from the switch of the transmitter and speed control lever turn on the power of the transmitter If the above does not restore the normal operation...

Page 21: ...on operation 53 58 Swing operation 54 59 Accelerating operation 60 63 First change to the manual operation Then after the operation lever that corresponds to the error number is manually returned to t...

Page 22: ...he lock nut and lightly tighten the screw inside until it cannot be turned any longer Fastening the screw too tight may cause operation failures Make sure to lightly tighten the screw 2 After manually...

Page 23: ...When no operation is made for approximately one hour the power of the transmitter is automatically turned off to save battery consumption Turn on the power again The power is turned off during the ra...

Page 24: ...e generating device such as a revolving light electric fan or vehicle s air conditioner is used nearby the radio control operation is influenced by the source Turn off the noise generating device when...

Page 25: ...control lever causing operation failures or malfunctions of the crane 3 Is the fixing screw of the transmitter s battery cover securely tightened A loose fixing screw of the transmitter s battery cove...

Page 26: ...26 MEMO...

Page 27: ...as Service Dept Tadano Ryogoku Bldg 4 12 Kamezawa 2 chome Sumida ku Tokyo Japan Tel 81 3 3621 7765 Tel fax 81 3 3621 7785 TADANO AMERICA CORP 333 Northpark Central Drive SuiteZ Houston Texas 77073 U S...

Page 28: ......

Reviews: