![Taconova Tacosol Load EXA L Manual Download Page 13](http://html1.mh-extra.com/html/taconova/tacosol-load-exa-l/tacosol-load-exa-l_manual_3167362013.webp)
13
Caution
The menu “1. Measurement values” serves to display the currently measured
temperatures.
The menu is closed by pressing “esc” or selecting “Exit measurement values”.
Selecting “Overview” or “esc” exits the Info mode.
If “Error” appears on the display instead of the measurement value, then there may be a defective or incorrect
temperature sensor. If the cables are too long or the sensors are not placed optimally, the result may be small
deviations in the measurement values. In this case the display values can be compensated for by making en-
tries on the controller. Follow the instructions under „6.19. - Sensor calibration“ on page 33.
What measurement values are displayed depends on the selected program, the connected sensors and the
speci
fi
c device design.
Measurement values
1. - Measurement values
2. - Statistics
The menu “2. Statistics” is used for function control and long-term monitoring of
the system.
The menu is closed by pressing “esc” or selecting “Exit statistics”.
Statistics
Caution
For analysis of the system data it is essential for the time to be set accurately on the controller. Please note that
the clock does not continue to run if the mains voltage is interrupted, and must therefore be reset. Improper
operation or an incorrect time may result in data being deleted, recorded incorrectly or overwritten.
The manufacturer accepts no liability for the recorded data!
2.1. - Operating hours
Display of operating hours of the solar pump connected to the controller; various time ranges (day-year) are available.
2.2. - Heat output
Display of the heat output of the system.
2.3. - Graphic overview
This provides a clearly-organised display of the data listed under 2.1-2.2 as a bar graph. Various time ranges are available for
comparison. The two left-hand keys can be used to page through the data.
Resetting and deleting the individual analyses. The function “All statistics” clears all analyses but not the error messages.
2.5. - Reset/clear
2.4. - Message log
Display of the last 20 events occurring in the system with indication of date and time.