Taconova TACOFLOW3 MAX Instructions For Installation And Use Manual Download Page 44

TACOFLOW3 MAX / MAX PRO  

42

Instructions for installation and use

MKTG-TRA-MAN-E9150400-10/2019-ENG

15 

INSTRUCTIONS FOR DECOMMISSIONING, DISMANTLING AND DISPOSAL

WARNING

IT IS FORBIDDEN TO DISPOSE OF LIQUIDS AND RESIDUAL OIL INTO THE ENVIRONMENT.

WARNING

ONLY DISPOSE OF THE PRODUCTS CONSIDERED TO BE POLLUTING AND HAZARDOUS BY COMMISSIONING AUTHORISED AND 

SPECIALISED FACILITIES FOR THE DIFFERENT TYPES OF PRODUCT.
SEPARATE THE PARTS THAT MAKE UP THE CIRCULATOR ACCORDING TO THE DIFFERENT TYPES OF CONSTRUCTION MATERIAL 

(PLASTIC, IRON, ETC.).
WHEN DEMOLISHING THE LINE, IT IS MANDATORY TO COMPLY WITH THE PROVISIONS OF THE CURRENT REGULATIONS.

ATTENTION

ALL COMPONENTS OF THE CIRCULATOR MUST BE IDENTIFIED ACCORDING TO THE DEFINITIONS OF THE “EWC CODES” 

(EUROPEAN WASTE CATALOGUE) AND DISPOSED OF BY COMMISSIONING AUTHORISED AND SPECIALISED FACILITIES, IN 

STRICT COMPLIANCE WITH THE REGULATIONS IN FORCE IN THE COUNTRY OF DEMOLITION.

ATTENTION

WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) MUST BE DISPOSED OF IN STRICT COMPLIANCE WITH THE 

REGULATIONS IN FORCE IN THE COUNTRY WHERE THE LINE IS DEMOLISHED.

Summary of Contents for TACOFLOW3 MAX

Page 1: ...HEATING AND COOLING CIRULCATION PUMP CONTACT AND FURTHER INFORMATION INSTRUCTIONS FOR INSTALLATION AND USE ENG...

Page 2: ......

Page 3: ...Series 8 3 3 Model 8 4 CONFORMITY 9 4 1 EU Declaration of Conformity 9 4 2 Nameplate and CE marking 10 5 DESCRIPTION OF THE CIRCULATOR 11 5 1 Safety state of the circulator 11 5 2 Intended use 11 5 3...

Page 4: ...3 Setting the circulator to MAX mod 33 12 3 External connection for 0 10 V PWM signal 34 12 3 1 Standby mode MAX PRO Mod 35 12 3 2 Analogue input 35 12 3 3 0 10V input 35 12 3 4 PWM input 36 12 3 5 An...

Page 5: ...ffer you all our experience and knowledge for the best solution to all your questions WARNING IT IS FORBIDDEN TO USE THE CIRCULATOR BEFORE IT IS COMMISSIONEDAND THE TEST CERTIFICATE IS SIGNED 1 MANUFA...

Page 6: ...2 1 TO REQUEST A COPY OF THE MANUAL FROM THE MANUFACTURER IN THE CASE OF LOSS OR DETERIORATION THIS MANUAL REFLECTS THE STATE OF THE ART OF THE CIRCULATOR AT THE TIME OF MARKETING AND CANNOT BE CONSI...

Page 7: ...ment provided exclusively by the Manufacturer and or by the Service Centre equipped with the personal protective equipment PPE indicated in chap 8 ELECTRICAL MAINTENANCE TECHNICIAN A qualified technic...

Page 8: ...ating it is mandatory to read the manual In order to use the circulator safely it is mandatory to read and fully understand this instruction manual and the attached technical documentation Signal indi...

Page 9: ...olds ownership and copyright of this manual It is forbidden to hand over to third parties or reproduce this document use its content or otherwise disclose it to third parties without authorisation Any...

Page 10: ...TacoFlow3 3 3 MODEL MAX MAX PRO Features Nominal diameter ND suction delivery mm MAX Head dm Centre distance mm Connection Electrical connection Communication 25 100 180 G 11 2 Plug Play PWM 0 10 V 80...

Page 11: ...of the laws of the Member States relating to electromagnetic compatibility recast 2011 65 EU Directive of the European Parliament and of the Council of 8 June 2011 on the restrictionofusingcertainhaz...

Page 12: ...the circulator in accordance with the Directives indicated in the EU Declaration of Conformity ATTENTION UPON PURCHASE MAKE SURE THAT THE CIRCULATOR BEARS THE NAMEPLATE AND CE MARKING IF NOT IMMEDIAT...

Page 13: ...e circulator 3 Wait for the circulator to cool 5 2 INTENDED USE Application Civil and or industrial heating systems Place of use The circulator must be placed indoors in a sufficiently lit and ventila...

Page 14: ...IRCULATOR 3 ITIS FORBIDDENTO USETHE CIRCULATOR WITHOUTGUARDSAND PROTECTIVE DEVICES OR EQUIPPED WITH INEFFECTIVE GUARDS AND DEVICES 4 IT IS FORBIDDEN TO NEUTRALISE TAMPER WITH MANIPULATE OR BYPASS THE...

Page 15: ...TACOFLOW3 MAX MAX PRO MKTG TRA MAN E9150400 10 2019 ENG Instructions for installation and use 13 5 4 DIMENSIONS FIG 2 FRONT SIDE LH SIDE PLAN Dimensions...

Page 16: ...temp 50 C bar MPa 0 3 0 03 Suction inlet pressure 1 with liquid temp 95 C bar MPa 1 0 0 10 Suction inlet pressure 1 with liquid temp 110 C bar MPa 1 5 0 15 Specific EEI 2 IEE 0 22 Mass kg 3 5 1 To av...

Page 17: ...lycol with percentages that are not higher than 30 TAB 8 Suitable liquids for pumping WARNING IT IS FORBIDDEN TO USE LIQUIDS OTHER THAN THOSE INTENDED BY THE MANUFACTURER WARNING IT IS MANDATORY FOR T...

Page 18: ...TACOFLOW3 MAX MAX PRO 16 Instructions for installation and use MKTG TRA MAN E9150400 10 2019 ENG 5 10 NAME OF THE MAIN COMPONENTS FIG 3 BOTTOM VIEW FRONT SIDE LH SIDE PLAN Name of the main components...

Page 19: ...value 8 Motor cover Covers the electric motor 9 Electrical connector Allows the electrical power cables to be connected 10 Power connection cover It holds the plug play connector 11 Signal output cap...

Page 20: ...They secure the cover to the container N 4 3x25 mm 1 05 Nm 0 15 Nm 2 Control shell unit It houses the circulator control board 3 Power shell unit Contains the power electronic board 4 Connector L N C...

Page 21: ...e LED It indicates the operating state of the circulator see par 5 12 1 4 DOWN button They select the desired value 5 UP button 6 SET button Confirms the desired value TAB 12 Command and control devic...

Page 22: ...d reduction in the flow rate and increases proportionally to the increase of the system heat demand increase in the flow rate Blue Min max fixed speed mode The circulator maintains a fixed speed regar...

Page 23: ...NS FIG 5 FRONT SIDE LH SIDE Guards and protective devices Ref Name Main functions 1 Motor cover Covers the electric motor 2 Power connection cover It holds the plug play connector 3 Quick connector Co...

Page 24: ...isks described below persist DANGER TO MINIMISE THE EXPOSURE TO RESIDUAL RISKS IT IS FORBIDDEN TO USE THE CIRCULATOR IN AN INCORRECT WAY OTHER THAN THE INTENDED USE INDICATED BY THE MANUFACTURER SEE P...

Page 25: ...forced toe Body protection protective clothing Face protection protective shield if necessary TAB 16 Personal Protective Equipment PPE 9 TRANSPORT AND HANDLING Generally the circulator is transported...

Page 26: ...VARIOUS TYPES OF MATERIAL IN STRICT COMPLIANCE WITH THE LAWS IN FORCE IN THE COUNTRY OF USE DANGER IT IS FORBIDDEN TO HANDLE THE CIRCULATOR BY GRASPING THE HEAT SINK FIG 6 REF 1 THE ELECTRONIC BOARD C...

Page 27: ...CHNICIAN AND THE ELECTRICAL MAINTENANCE TECHNICIAN 11 1 MOUNTING POSITIONS WARNING IT IS MANDATORY TO INSTALL THE CIRCULATOR WITH THE AXIS OF THE MOTOR SHAFT HORIZONTAL TO THE FLOOR THE CIRCULATOR MOU...

Page 28: ...S MANDATORY TO CHECK THAT THE CIRCULATOR IS IN THE SAFETY STATE BEFORE PERFORMING MAINTENANCE OR ADJUSTMENTS THERE ARE RESIDUAL RISKS 1 2 AND 3 SEE CHAP 8 Adjust the motor body as follows 1 Unscrew an...

Page 29: ...9 Ref 2 3 Place the circulator on the pipes without creating tension and with the motor shaft positioned horizontally FIG 9 Ref 3 4 Insert the gaskets FIG 9 Ref 4 5 Tighten the pipe unions with adequa...

Page 30: ...THE CLIENT OR WITH A PLUG CONNECTED TO THE POWER CABLE THAT GUARANTEES THE DISCONNECTION OF THE POWER IN CASE OF MAINTENANCE OR SHUTDOWN THE ELECTRICALCONNECTION OF THE CIRCULATOR TO THE MAINS IS SOLE...

Page 31: ...or brown wire phase to terminal L FIG 10 Ref 3 4 Connect the yellow green wire earth to terminal G FIG 10 Ref 4 5 Connect the terminal board in the appropriate seat 6 Tighten the cable gland manually...

Page 32: ...PERATIONS BEFORE STARTING THE CIRCULATOR Ref Checks and operations 1 Make sure there are no unauthorised people near the circulator 2 Make sure that all parts of the circulator are intact 3 Make sure...

Page 33: ...D lights up on the circulator 12 2 1 VENTING THE SYSTEM At start up the circulator can be noisy due to air in the system Air in the system is indicated by the white LED turning on and flashing in the...

Page 34: ...t the new operating mode and the desired value for the constant proportional and variable power curves see display below 3 Press the SET button to confirm the desired operating mode and value Orange C...

Page 35: ...g curve depends on the system characteristics and on the system heat demand LED Position Function Purple ActiveADAPT Yellow 010 V or PWM external input Orange Lower Constant Curve CI Intermediate Cons...

Page 36: ...or cover FIG 11 Ref 2 2 Unscrew a signal output cap FIG 11 Ref 3 3 Disconnect the connector FIG 11 Ref 4 from the electronic board FIG 11 Ref 5 4 Insert the cable FIG 11 Ref 6 in the cable gland M12x1...

Page 37: ...ly The type of signal is automatically selected by the circulator without the operator s intervention 12 3 3 0 10V INPUT The circulator operates at variable speed according to the DC input voltage The...

Page 38: ...NALOGUE OUTPUT The circulator has an analogue output to indicate the operating status and the presence of any errors Voltage State 0 V Circulator off not powered 2 V Circulator powered in standby 4 V...

Page 39: ...CHNICAL MENU AND RESUMES NORMAL OPERATION FIG 14 Technical menu Parameter Meaning T 0 Display Firmware Version T 1 Inverter Firmware Version T 2 Unit of measurement shown on the display SI Syst me int...

Page 40: ...s off on the circulator DANGER AFTER HAVING STOPPED THE CIRCULATOR AND HAVING INDICATED THE EMERGENCY TO THE MANAGER IT IS MANDATORY TO STOP ANY INTERVENTION ON THE CIRCULATOR UNTIL THE MANAGER GIVES...

Page 41: ...pressure is insufficient Cavitation Increase the system input pressure within the allowable range TAB 20 par 12 2 3 On Foreign bodies in the impeller Check if there are foreign bodies inside the pump...

Page 42: ...MUST ONLY PERFORM THE MAINTENANCE REQUIRED ACCORDING TO THEIR SPECIFIC PROFESSIONAL SKILLS AND AS CONSENTED BY THE MANAGER WARNING IT IS FORBIDDEN TO USE PRODUCTS OTHER THAN THOSE INTENDED BY THE MAN...

Page 43: ...THE GUARDS AND PROTECTIVE DEVICES MUST BE CARRIED OUT BEFORE EVERY START UP AND WITH THE CIRCULATOR IN THE SAFETY STATE SEE PAR 5 1 DANGER DURING VERIFICATION IT IS FORBIDDEN TO LEAVE THE CIRCULATOR U...

Page 44: ...HE CIRCULATORACCORDING TO THE DIFFERENT TYPES OF CONSTRUCTION MATERIAL PLASTIC IRON ETC WHEN DEMOLISHING THE LINE IT IS MANDATORY TO COMPLY WITH THE PROVISIONS OF THE CURRENT REGULATIONS ATTENTION ALL...

Page 45: ...AN E9150400 10 2019 ENG Instructions for installation and use 43 16 SPARE PARTS 16 1 ORDERING METHOD ATTENTION ORIGINALACCESSORIESAND SPARE PARTS FORANY REPLACEMENT MUST ONLY BE REQUESTED FROM THE MAN...

Page 46: ...RKERS IN THE WORKPLACE THE EMPLOYER DECLARES TO HAVE PROVIDED THIS MANUAL TO THE AUTHORISED OPERATORS FOR CORRECT INFORMATION AND TRAINING ON USE AND MAINTENANCE OF THE LINE Authorised operators Date...

Page 47: ......

Page 48: ...Taconova reserves the right to make changes without prior notice ul Tr jpole 3 61 693 Pozna Polska T 48 61 227 84 21 polska taconova com...