8
In order to turn off the vacation leak mode follow instruc-
tions in 5.5 and set vacation leak to - - (Figure 9).
When the FloodBreaker has detected a leak and isolated
the system it can be re-opened by pressing the button
(Figure 10).
1. Unlock the keyboard. Press the button until reach-
ing the manual menu identified as Ab (Figure 11).
2. Press the button again to view the current position.
3. Use the or button to change the FloodBreaker‘s
current position. P1 is the open position and P2 is the
closed position (Figure 12).
4. Once the desired position is displayed press the
button to activate and save the setting.
In order to view the advanced menu, press and hold the
button. While holding the mode button, press the but-
ton three times and then release both buttons. You may now
scroll through the advanced menu.
If you wish to make adjustments to any settings in the
advanced menu, it must be unlocked per the user menu
instructions in section 4.1.
Table 2
(UL) Vacation Leak
Settings
Approximate
Gallons
– –
Deactivated
1
3
2
5
3
8
4
11
5
13
6
16
7
18
8
21
9
24
10
26
Note: When vacation leak protection mode is activated, it
overrides any standard leak protection.
5.6 Deactivating vacation leak
protection
Figure 9
5.7 Re-opening after a leak shut-off
Figure 10
5.8 Opening and closing the
FloodBreaker
Figure 11
Figure 12
6. Advanced Menu Settings
Note: Changes should only be made to Advanced Menu
Setting after reading and understanding these functions.
Summary of Contents for FloodBreaker
Page 2: ...2 ...