13
Press the mode button to display the software version
(Figure 25).
Press the mode button to display the battery voltage remain-
ing (Figure 26).
The FloodBreaker can save up to 8 alarm messages. Scroll
through the saved messages by repeatedly pressing the
mode button. If no messages have been saved, FF will be
displayed.
The manual key is provided in the event that the
FloodBreaker has closed and no power is available to open
the valve.
Remove the two cover halves (Figure 27).
The key is located on the inner side of the left cover
(Figure 28).
Remove the locking clamp from the control head so that it
can be lifted off. Lift off the control (Figure 29).
Insert the key by aligning the key slot with the shaft and turn
it in the direction shown by the arrows to open (Figure 30).
Water flow should be back to normal.