Additional functions
43
Additional functions
Programming procedure („Menü“)
Position of selector switch: Vers. / Menü
Pressing the yellow „
Eingabe
“ key for 2 seconds causes entry or exit
to/from the sub menu
normal (short) pressing switches from one position to the next
The value can be changed with the blue keys
ab/auf
(down/up).
ew
ex works = original setting by the factory
E5.0
–
software version
of controller: It shows the „intelligence“ of the
device and cannot be changed.
Pressing the yellow „
Eingabe
“ key for 2 seconds causes entry to the
sub menu section
SEn
–
sensor type
: Selection of sensor type KTY (=semi-conductor)
or Pt1000 (=platinum)
ew
= all sensors Pt1000
Entry to sub menu „
sensor type
“
FCo
–
function control
: Activating of the detection function (sensor
failure, circulation problems). Error messages are displayed, if a failure
occurs.
ew
= function control deactivated
Entry to sub menu „
function control
“
Utb
–
collector excess temperature limit
– switch-off function when
too high collector temperature occurs.
ew
= collector excess temperature limit function
active
Entry to sub menu „
collector excess temperature limit
“
StF
–
start function
: settings for start-up of pumps in time for solar
power systems (ideal for tube collectors)
ew
= start function deactivated
Entry to sub menu “
start function
”
Pri
–
solar priority
: settings for priority conditions
ew
= all values are set to „standard system“
Entry to sub menu „
solar priority
“
PnL
–
after-running time
: Settings for each output
ew
= no after-running times