5
Safety requirements:
All installation and wiring work on the controller must only be carried
out in a zero-volts state.
The opening, connection and commissioning of the device may only be
carried out by competent personnel. In so doing, all local security re-
quirements must be adhered to.
The device corresponds to the latest state of the art and fulfills all necessary safety condi-
tions. It may only be used or deployed in accordance with the technical data and the safety
conditions and rules listed below. When using the device, the legal and safety regulations
apposite to the particular use are also to be observed.
►
The device must only be installed in a dry interior room.
►
It must be possible to isolate the controller from the mains using an all-pole isolating de-
vice (plug/socket or double pole isolator).
►
Before starting installation or wiring work, the controller must be completely isolated from
the mains voltage and protected against being switched back on. Never interchange the
safety extra-low voltage connections (sensor connections) with the 230V connections. De-
structive and life-threatening voltages at the device and the connected sensors may occur.
►
Solar thermal systems can become very hot. Consequently there is a risk of burns. Take
care when fitting temperature sensors!
►
For safety reasons, the system should only be left in manual mode when testing. In this
operating mode, no maximum temperatures or sensor functions are monitored.
►
Safe operation is no longer possible if the controller or connected equipment exhibits visu-
al damage, no longer functions or has been stored for a lengthy period of time under un-
suitable conditions. If this is the case, place the controller and equipment out of service
and secure against unintentional use.
Maintenance:
The system does not require maintenance if handled and used properly. Use a cloth mois-
tened with soft alcohol (such as spirit) to clean. Do not use cleansers and/or solvents such as
trichlorethene.
As none of the components relevant to accuracy are under loads when used properly,
they have a long service life without much drift. The unit thus does not have any adjustment
options. No adjustments are needed.
The design characteristics of the unit must not be changed during repairs. Spare parts
must correspond to the original spare parts and be as good as new.