EU Declaration of Conformity

 

Document number/date: 

TA17025 / 02/02/2017 

Manufacturer: 

Technische Alternative RT GmbH 

Address: 

A-3872 Amaliendorf, Langestrasse 124 

The manufacturer bears sole responsibility for issuing this Declaration of Conformity.  

Product designation: 

UDV 

Brand names: 

Technische Alternative GmbH. 

Product description: 

3-way valve with drive unit 

The item described above complies with the following directives: 

2014/35/EU 

Low Voltage Directive 

2014/30/EU 

Electromagnetic compatibility 

2011/65/EU 

RoHS directive on restricting the use of certain hazardous substances 

2014/68/EU 

Pressure Equipment Directive 

The following harmonised standards have been applied: 

EN 60730-1:2011 

Automatic electrical controls for domestic and similar applications 

–  

Part 1: General requirements 

EN 60730-2-14:1997 + 
A1:2001 + A11:2005 + 
A2:2008 

Automatic electrical controllers for domestic and similar applications 

– 

Part 2-14: Particular requirements for electric actuators 

EN 61000-6-3: 2007 
                +A1: 2011 
                + AC2012 

Electromagnetic compatibility (EMC) 

– Part 6-3: Generic standards – 

Emission standard for residential, commercial and light-industrial 
environments 

EN 61000-6-2: 2005 
                + AC2005 

Electromagnetic compatibility (EMC) 

– Part 6-2: 

Generic standards 

– Noise immunity for industrial environments 

EN 50581: 2012 

Technical documentation for the assessment of electrical and electronic  
products with respect to the restriction of hazardous substances 

Attachment of CE label: 

On packaging, operating instructions and type plate 

 

 
 
 

Issued by: 

Technische Alternative RT GmbH 
A-3872 Amaliendorf, Langestrasse 124 

Authorised signature

 

 

 

Dipl.-Ing. Andreas Schneider, Managing Director  
02/02/2017 
 
This declaration certifies conformity with the listed directives, but does not guarantee any properties. 

The safety instructions in the product documents supplied must be observed. 

 

 

 

Summary of Contents for UDV

Page 1: ...UDV Version 1 0 EN Universal 3 way valve Installation instructions en...

Page 2: ......

Page 3: ...valve 5 Valve drive unit connection 6 Camshaft 6 Use of locking plate as a lever 7 Selecting the rotation angle 90 or 180 7 Control cam valve position indicator 9 Mounting the drive motor 10 Electric...

Page 4: ...bits visual damage no longer functions or has been stored for lengthy periods under unsuitable conditions If this is the case disable the 3 way valve and secure against unintentional use Maintenance T...

Page 5: ...5 Structure and assembly of the 3 way valve Upper casing section Drive motor Drive shaft Camshaft Terminals Motor terminals Locking plate Valve body with ball valve 2 limit switches...

Page 6: ...connection the locking plate must be inserted into the slot provided in the upper casing section Examples Camshaft When positioning the camshaft on the valve shaft ensure that the marking on the valv...

Page 7: ...ith the help of the locking plate If pliers are used they could damage the valve shaft Selecting the rotation angle 90 or 180 The factory setting for the ball valve rotation angle is 180 This rotation...

Page 8: ...ings out of the disc and slide it into the groove provided for this purpose View of the correctly inserted 90 control cam If the control cam has been broken out but is no longer required then it can b...

Page 9: ...upper casing section is attached the current position of the valve is indicated by the camshaft disc In the following example the upper part of the cross is red which means that this branch is closed...

Page 10: ...the camshaft insert the drive shaft into the motor shaft Then secure the motor to the lower casing section with 2 fixing screws The motor is connected to the motor terminals at the factory These conne...

Page 11: ...rn spring 3 point control signal In this case one core is responsible for clockwise rotation and another for anti clockwise rotation Consequently 3 wires are required for switching the valve No earth...

Page 12: ...e other end position virtual return spring Normally a wire jumper needs to be established from above across the neutral connection and the second terminal No earth connection is required because the d...

Page 13: ...insulated Nominal operating mode S2 short term operation Max ambient temperature 0 C to 45 C Medium temperature 0 C to 100 C Max operating pressure 6 bar Runtime 90 180 17 s 34 s Connection thread 3 4...

Page 14: ...14 Dimensions...

Page 15: ...A11 2005 A2 2008 Automatic electrical controllers for domestic and similar applications Part 2 14 Particular requirements for electric actuators EN 61000 6 3 2007 A1 2011 AC2012 Electromagnetic compa...

Page 16: ...instructions or incorrect maintenance 4 The guarantee will become void if repairs or actions are carried out by people who are not authorised to perform them or have not been so authorised by us or i...

Reviews: