background image

JW weighing scales operation manual

             

                     

         

     

                   

      REV: C1, June 2012                     

                                                   

JW weighing scales operation manual

 

 

CONTENTS 

 

1. 

INTRODUCTION…………………………………………………………1 

2. 

NAME  AND  FUNCTIONS…………………………………………….2 

 

2.1 

Key  Board………………………………………………………….2 

 

2.2 

Display………………………………………………………………2 

3. 

OPERATION………………………………………………………….4 

 

3.1 

Basic  Operation…………………………………………………….4 

 

3.2 

Percent  Weighing…………………………………………………..5 

 

3.3  Parts  Counti

ng………..…………………………………………….5 

 

3.4 

Check  Weighing.…………………………………………………6 

 

3.5 

Accumulation……………..………………………………………..6 

4. 

CALIBRATION………………………………………………………….8 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for JW

Page 1: ... JW Weighing Scales ...

Page 2: ...2 JW weighing scales operation manual CONTENTS 1 INTRODUCTION 1 2 NAME AND FUNCTIONS 2 2 1 Key Board 2 2 2 Display 2 3 OPERATION 4 3 1 Basic Operation 4 3 2 Percent Weighing 5 3 3 Parts Counting 5 3 4 Check Weighing 6 3 5 Accumulation 6 4 CALIBRATION 8 ...

Page 3: ...le capacity Place the calibration weight on the platform Press ZERO to confirm when display gets stable Display will be show full of the scale capacity Place the full capacity of the calibration weight on the platform Press ZERO to confirm when display gets stable Linear Calibration has finished and will start self test to come to normal weighing 8 1 INTRODUCTION The JW series weighing scales are ...

Page 4: ... the load from the platform The weighing value will be stored into the memory and display will be show ACC 1 followed by the weighing value Then display will be come to normal weighing The balance should be return to zero or a negative value before another sample can be stored It can continue the process It may take up to 99 entries or up to the capacity of the display 4 CALIBRATION Normal Calibra...

Page 5: ...nnected data will be print Remove the load from the platform The balance should be return to zero or a negative value before another sample can be stored It can continue the process It may take up to 99 entries or up to the capacity of the display Weight 6 3 OPERATION Initial Start up Warm up time of 15 minutes stabilizes the measured values after switching on 3 1 Basic Operation 2 Power ON OFF Po...

Page 6: ... weight display will return to 0 00 Place a sample display will be show the percentage of the sample as per reference weight To return to normal weighing mode press key 4 3 3Parts Counting As per reference weight balance will calculate average piece weight So it should know the average piece weight for a reference weight The higher quantity of the reference weight is better to get the exact higher...

Reviews: