1. T-ONE kit contents
1 T-ONE electronic stimulator;
4 connection cables, for the transmission of electric impulses;
2 packages containing 4 pre-gelled self-adhesive 48x48 mm electrodes;
2 packages containing 4 pre-gelled self-adhesive 50x90 mm electrodes;
1 packages containing 8 round pre-gelled self-adhesive 32 mm diameter;
1 battery charger;
4 rechargeable Ni-Mh batteries AA (8 for model MEDI-PRO)
1 T-ONE user manual;
1 electrode position manual;
1 Ionophoresis Kit;
1 carry bag;
Spare parts available:
• Pre-gelled self-adhesive electrodes 48x48mm, 50x90mm, round 32mm
• Ionophoresis pads: 60x80mm • 80x120mm;
• Elastic band for Ionophoresis treatment 80 mm high (code FI80X60)
• Set elastic band for legs drainage (codes FC250-265 and FP235-245);
2. Purpose.
The T-ONE electronic stimulator is a medical device specifically intended for adults with
adequate knowledge of the device acquired from reading the manual for domestic use.
T-ONE is used to apply electrical microimpulses, capable of producing energy, to the human
body. This energy, modulated in accordance with parameters typical to each impulse, can be
used for various purposes, from pain reduction to winding-down exercises, from muscle
strengthening to drainage, from isotonic exercises to treating haematomas, to the treatment of
imperfections using the beauty programs. We recommend to consult your doctor before using
TENS and REHAB programs.
Contraindications.
This device must not be used by people with a pace-maker, epileptics, pregnant women,
people with a high temperature, anxious people or people suffering from heart disease,
phlebitis, thrombophlebitis or serious illnesses.
In the event of injury, muscle stress or any other health problem use the device only under
medical supervision.
The ionophoresis program uses monophasic impulse, so it is polarizing: do not use near
metallic prosthesis under skin (minimum 10 cm from metallic prosthesis).
Side effects
No significant side effects are known of. Some particularly sensitive people have reported skin
redness in the area where the electrodes were positioned: the redness usually disappears a
few minutes after the end of the treatment. Should the redness persist please consult a doctor.
In rare cases, stimulation carried out in the evening can cause some people to experience
difficulty in falling asleep. If this occurs, suspend the treatment and consult a doctor.