Translation of the Original Operating Instructions
7
Displays the status of each light after the network is successfully connected.
No.
Description
Power light
Red light
Green
light
Blue light
WIFI/
Bluetooth
Remarks
8.5.1
Switching the
pump on/off
manually
Operation by hand
8.5.2
Switch on via
app
WIFI or
Bluetooth
connection
Bluetooth is available
after approx. 3 minutes
without WIFI and cannot
be set as a timer.
8.5.3
Switch off via
APP
8.5.4
Switch on by
timer
If the WIFI connection is
interrupted, the pump will
operate according to the
timer setting originally set.
If the pump is
disconnected from the
mains, the timer setting
must be reset.
8.5.5
Switch off by
timer
8.6.
Protection mode:
The pump is equipped with various electronically controlled protection mechanisms:
-
Dry running or idle running:
If the pump is operated for 5 minutes without water, the electronics automatically switch off the pump. The
error mode is signaled on display 1 according to 8.6.1. Before the pump is reactivated, it is necessary to
determine the cause of the error message and to correct the error. Restarting the pump is only possible
manually by pressing the ON/OFF switch or by briefly disconnecting the pump from the power supply.
-
Overload or blockage:
If the pump is blocked or overloaded for 5 seconds during operation, the overload or blocking protection is
activated. Before the pump is reactivated, it is necessary to determine the cause of the error message and
correct the error. After the problem has been corrected, a reset is required by pressing the ON/OFF switch on
the pump or by disconnecting and reconnecting the power plug. This error is signaled as shown in 8.6.2
No.
Description
Power light
Red light
Green light
Blue
light
Remarks
8.6.1
After 5 min
without load, dry
run or no-load
protection is
activated
3 m
Trigger current is
fixed per factory
setting
8.6.2
Overload or
blocking
protection
3 m
5 s
Overload or locked
rotor for 5 seconds,
start-up protection
and pump
shutdown.
8.7.
Error mode:
-
If the pump loses the WIFI connection, indicator 1 will light up as shown at 8.7.1. The pump will still continue
to operate according to the set program as long as there is no disconnection from the network.
-
It will affect the execution of the timer function if the network is disconnected and a power failure occurs or
the mains plug is pulled. After the network connection is restored, the timer function must be reactivated. The
restored network connection is displayed as shown in 8.7.2.
-
After 3 minutes of network disconnection, the Bluetooth connection mode is activated, in this case the app
function is only limited to switching the pump on and off, timer control and displaying the working current,
voltage and total operating time is not possible in Bluetooth connection mode.
19