5
contained in the liquid discharged will speed up the process of wearing and tearing and accelerate the drop in
performance.
If the unit is operated properly, it will not require any maintenance. Where applicable, you may clean the hydraulic
part from sediments and dirt. This can be done by counter-flushing the unit with clear water using a hose to be
connected through the pressure port of the pump. To remove tenacious dirt, the foot of the pump (8) can be
removed by loosening the screws located at the bottom of the pump. To avoid any hazard, any further
disassembly as well as the replacement of parts must only be done by the manufacturer or a by an authorized
service provider. Water left in the pump may freeze in case of frost and thus cause considerable damage.
Therefore, the pump must be removed from the liquid being discharged and fully drained when temperatures are
below the freezing point of the liquid. Please store the pump in a dry, frost-protected place. In the case of
malfunction, you should first of all check whether it was caused by an operating error or some other reason which
cannot be attributed to a defect of the device - for instance a power failure. The list below shows some possible
malfunctions of the device, possible causes and tips on their elimination. All the measures referred to may only be
carried out with the pump being separated from the electrical mains. If you yourself feel unable to eliminate any of
these malfunctions, please contact the customer service department or your point of sales. Any repair beyond the
scope specified below must only be performed by qualified staff. Please bear in mind that all warranty claims will
become void in the case of damage caused by inappropriate repair attempts, and that we decline any liability for
any ensuing damage.
MALFUNCTION
POSSIBLE CAUSE
ELIMINATION
1. The pump is not discharging
any liquid, the motor is not
running.
1. No current.
2. Thermal motor protection feature has
triggered.
3. The capacitor is defective.
4. The pump wheel is blocked.
5. The floating switch is defective.
1. Please use a device complying with GS
(German technical supervisory authority) to
check for the presence of voltage (safety
information to be observed!). Please verify
the correct position of the plug.
2. Separate the pump from the electrical mains,
allow the system to cool down, eliminate
cause.
3. Please contact the customer service
department.
4. Eliminate blocking of pump wheel.
5. Please contact the customer service
department.
2. The motor is running, but the
pump is not discharging any
liquid.
1. The intake openings are clogged.
2. The pressure line is clogged.
3. Air penetrates into the pump body.
4. The min. suction level was fallen short of;
possibly incorrect setting of the floating
switch, motion of floating switch restricted,
floating switch defective.
5. Check valve (non-return valve), if present,
is blocked or defective.
1. Remove possible congestion.
2. Remove possible congestion.
3. Start pump several times so that the entire air
will be driven out.
4. Make sure that the minimum suction level is
not fallen short of; if necessary, adjust
floating switch properly or make sure that it
can move freely; in the case of a defective
floating switch, please contact customer
service.
5. Eliminate blocking of the check valve (non-
return valve) or replace, if damaged.
3. The pump stops after a short
time of operation because the
thermal motor protection
feature has triggered.
1. The electrical supply does not correspond
to the information given on the type plate.
2. Pump or intake openings are blocked by
solids.
3. Liquid is too viscous.
4. Temperature of the liquid is too high.
5. Pump is running dry.
1. Please use a device complying with GS
(German technical supervisory authority) to
check the voltage of the lines of the
connection cord (safety information to be
observed!).
2. Remove possible congestion.
3. Pump may not be suitable for this liquid. If
feasible, the liquid should be thinned.
4. Make sure that the temperature of the liquid
being pumped does not exceed the max.
admissible value.
5. Eliminate causes of dry-running.
4. Intermittent or irregular
operation.
1. Pump wheel obstructed by solid matters.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Mains voltage out of tolerance.
5. Motor or pump wheel defective.
1. Remove solids.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Make sure that mains voltage matches that
indicated on the type plate.
5. Please contact the customer service
department.
12
Summary of Contents for Maxima 180 PX
Page 40: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 6 10 7 11 7 1 RCD FI 30 mA 38...
Page 42: ...3 4 5 5 1 5 2 1 5 3 5 4 2 3 4 5 40...
Page 43: ...4 4 13 5 5 6 6 FI 30 mA DIN VDE 0100 739 H07RN F 3 x 1 0 mm 7 41...
Page 44: ...5 230V AC T I P MAXIMA 8 8 service 42...
Page 46: ...7 1 2 3 10 www tip pumpen de 11 PDF e mail service tip pumpen de 2012 19 EU 44...
Page 71: ...1 T I P 1 1 2 2 3 2 4 2 5 3 6 4 7 4 8 4 9 6 10 6 11 6 1 RCD FI 30 mA 8 69...
Page 73: ...3 5 5 1 5 2 1 5 3 5 4 2 3 4 5 4 13 5 5 71...
Page 74: ...4 6 6 Fl 30 mA DIN VDE 0100 739 VDE H07RN F 3 x 1 0 mm 7 230V T I P MAXIMA 8 72...
Page 101: ...1 T I P 1 1 2 2 3 2 4 2 5 3 6 4 7 4 8 5 9 6 10 7 11 7 1 RCD 30 99...
Page 103: ...3 5 5 1 5 2 1 5 3 5 4 2 3 4 5 4 13 101...
Page 104: ...4 5 5 6 6 FI 30 DIN VDE 0100 739 H07RN F 3 x 1 0 VDE 7 230 T I P MAXIMA 102...
Page 105: ...5 8 8 1 1 2 3 4 5 t 1 2 3 4 5 2 1 2 3 4 5 1 2 3 4 5 103...
Page 107: ...7 10 www tip pumpen de 11 PDF service tip pumpen de 2012 19 EU 105...
Page 108: ...1 T I P 1 1 2 2 3 2 4 2 5 3 6 4 7 4 8 4 9 6 10 6 11 6 1 30 106...
Page 110: ...3 5 5 1 5 2 1 5 3 5 4 2 3 4 5 4 13 5 5 108...
Page 111: ...4 6 6 FI 30 DIN VDE 0100 739 H07RN F 3 x 1 0 VDE 7 230 T I P MAXIMA 8 109...
Page 113: ...6 9 1 2 3 10 www tip pumpen de 11 PDF service tip pumpen de 2012 19 EU 111...
Page 119: ...Notizen notes note notas...