t.amp S- 75 Owner'S Manual Download Page 7

Page 7

a

     

 

Connection for the power cord/supply voltage (AC230V~/50Hz)

 

   

 

with fuse holder

s

  CH-2 

 

Speakon speaker output channel 2,

for the connection of SPEAKON cables (1+ 2+ 1— 2—)

d

  CH-1 

 

Speakon speaker output channel 1,

for the connection of SPEAKON cables (1+ 2+ 1— 2—)

f

  CH-2 

 

Speaker terminals channel 2,

for terminal connection of speaker wires

g

  CH-1 

 

Speaker terminals channel 1,

for terminal connection of speaker wires

h

  GROUND LIFT  Toggle switch for earth potential

j

  (

stereo, parallel, bridged

)  Operation mode toggle switch (stereo, parallel or bridged)

k

  CH-2 

 

Jackplug input channel 2, symmetrical

l

  CH-2 

 

XLR input channel 2

1(

  0,77V | 1,4V 

Switch for input adjustment

2)

  CH-1 (MONO) 

XLR input channel 1

2!

  CH-1 (MONO) 

Jackplug input channel 1, balanced

4. Connection and operation 

Unpacking

Carefully open the package and check the contents for possible damage. Every one of our amplifiers 

is completely tested and thoroughly checked before leaving the factory and should therefore reach 

you in a faultless condition. If you should find any kind of damage promptly notify the shipping com

-

pany that transported the device to you. Only the consignee can assert a claim against the shipping 

company for damages incurred during transportation. Therefore keep the package and all packaging 

materials for their inspection. You should keep the package and packaging materials even if no 

damage is present. Should you need, at some time, to ship the device, package it exclusively in 

the original packaging.

Assembly

The power amplifier has a housing that allows for installation in standard 19" racks provided this 

exhibits a sufficient depth. The device requires one height unit, on the front panel you will see 4 

 

assembly openings for screwing to the rack rails. 

Important!

Keep these instructions for future reference.

 

X

Do not spill water or any other liquids over or in the device. Never operate the amplifier when

 

 

X

it is standing in a wet environment.

Make sure that the details for the supply voltage on the rear panel of the device correspond  

 

X

to the available supply voltage at the operation location. If in doubt ask an electrician.

Never apply a higher voltage to the device's input than that required for full drive.

 

X

Never direct the output signal of one power amplifier channel into the input of another power 

 

X

amplifier channel.

You must never switch together the output of one amplifier parallel or in series with the output 

 

 

X

of another amplifier.

Never connect the output of an amplifier with any kind of voltage source regardless of whether 

 

X

the amplifier is in operation or not.

Never connect a red characterized connection with earth.

 

X

Summary of Contents for S- 75

Page 1: ...S 75 S 100 S 150...

Page 2: ...llel and bridged operations are possible X X Speaker outputs for Speakon and terminals X X Contents Device features 2 1 Introduction 3 2 Notes on safety 4 3 Becoming acquainted with the operational co...

Page 3: ...ction We are pleased by your purchase and are proud of the long tradition of quality high class devices for which our company stands In order to get the best out of your amplifier you should read the...

Page 4: ...used for a long time for example during holidays Always grasp the power cord by the plug Do not pull on the cord itself and never touch the power cord with wet hands as this could result in a short c...

Page 5: ...clockwise w CH 1 Input level controller for channel 1 With this controller you decrease the input level in channel 1 to the respective dB value indicated on the scale At the right end stop the attenua...

Page 6: ...re is a malfunction in the device y BR Indicator for bridged mono operation In this case amplify both channels together with the signal at input 1 This leads to a significantly higher single channel o...

Page 7: ...herefore keep the package and all packaging materials for their inspection You should keep the package and packaging materials even if no damage is present Should you need at some time to ship the dev...

Page 8: ...tion to the devices If the electrical outlets appear for example corroded or have rusted contacts or they are equipped with cables that are too thin this will affect the performance ability of the dev...

Page 9: ...e sure that the mains voltage switch located on the underside of the device resp rearside for S 150 is in the position that corresponds to the actual mains voltage supply in Germany 230V If in doubt a...

Page 10: ...nel CH 2 Speaker Pole channel CH 1 When in operation you control the volume only with the input level controller CH 1 w the input level controller CH 2 r then has no function The input signal from cha...

Page 11: ...ion provisions you must also as the operator of this device always keep in mind the limits of the speakers Make sure that you never exceed the load limit of the connected speaker with the power from y...

Page 12: ...S Protection circuits Current limit with short circuit DC voltage fault fuse for supply voltage limiter temperature mains power transients Slow Start Control indicators Power green protection circuit...