t.amp S- 75 Owner'S Manual Download Page 6

Page 6 

r

 

CH-2

 

 

Input level controller for channel 2

With this controller you decrease the input level in channel 2 to the respective 

dB value indicated on the scale. At the right end stop the attenuation is "0" 

and the full signal is amplified with maximum power.

t

 

PRO

 

 

Indicator for activated circuit protection

This indicator lights up when, in either of the two channels, one of the following 

situations occurs:

• 3-5 seconds after switch on since now the speakers are still electrically 

disconnected from the power amplifier.

• The temperature of the power amplifier transistors exceeds 85°C.

• There is a malfunction in the device.

y

 

BR

  

 

Indicator for bridged mono operation

In this case amplify both channels together with the signal at input 1.  

This leads to a significantly higher single channel output power. 

 

Then do not connect any signals to channel 2.

u

 

PAR

 

 

Indicator for parallel mono operation

In this case amplify both channels with the signal at input 1. 

 

The amplified signal from input 1 is applied to both outputs (CH-1 & CH-2).

i

 

ON

  

 

Switch on indicator light

Lights up while the device is in operation.

o

 

POWER

   

ON / OFF switch

Move this switch to the "I" position to switch the device on. During switch on 

the circuit protection is activated. After a few seconds you will hear 2 "clicks" 

now the speakers are electrically connected with the power amplifier and the 

device is ready.

3.2 . . . rear

Summary of Contents for S- 75

Page 1: ...S 75 S 100 S 150...

Page 2: ...llel and bridged operations are possible X X Speaker outputs for Speakon and terminals X X Contents Device features 2 1 Introduction 3 2 Notes on safety 4 3 Becoming acquainted with the operational co...

Page 3: ...ction We are pleased by your purchase and are proud of the long tradition of quality high class devices for which our company stands In order to get the best out of your amplifier you should read the...

Page 4: ...used for a long time for example during holidays Always grasp the power cord by the plug Do not pull on the cord itself and never touch the power cord with wet hands as this could result in a short c...

Page 5: ...clockwise w CH 1 Input level controller for channel 1 With this controller you decrease the input level in channel 1 to the respective dB value indicated on the scale At the right end stop the attenua...

Page 6: ...re is a malfunction in the device y BR Indicator for bridged mono operation In this case amplify both channels together with the signal at input 1 This leads to a significantly higher single channel o...

Page 7: ...herefore keep the package and all packaging materials for their inspection You should keep the package and packaging materials even if no damage is present Should you need at some time to ship the dev...

Page 8: ...tion to the devices If the electrical outlets appear for example corroded or have rusted contacts or they are equipped with cables that are too thin this will affect the performance ability of the dev...

Page 9: ...e sure that the mains voltage switch located on the underside of the device resp rearside for S 150 is in the position that corresponds to the actual mains voltage supply in Germany 230V If in doubt a...

Page 10: ...nel CH 2 Speaker Pole channel CH 1 When in operation you control the volume only with the input level controller CH 1 w the input level controller CH 2 r then has no function The input signal from cha...

Page 11: ...ion provisions you must also as the operator of this device always keep in mind the limits of the speakers Make sure that you never exceed the load limit of the connected speaker with the power from y...

Page 12: ...S Protection circuits Current limit with short circuit DC voltage fault fuse for supply voltage limiter temperature mains power transients Slow Start Control indicators Power green protection circuit...

Reviews: