t.amp S- 75 Owner'S Manual Download Page 12

12. Technical Data

Model

S-75

S-100

S-150

Output power             stereo      8 Ω

 

                                                  4 Ω

 

                                                  2 Ω

 

                                   bridged   8 Ω

 

                                                  4 Ω

 

                                   parallel    2 Ω

 

                                                  1 Ω

2 x 45 W 

2 x 75 W 

2 x 90 W 

150 W 

220 W 

 

160 W

2 x 65 W 

2 x 100 W 

 

200 W 

 

200 W

2 x 85 W 

2 x 150 W 

2 x 200 W 

250 W 

400 W 

 

320 W

Frequency response

10 Hz - 50 kHz, -1,5 dB

Input sensitivity

0,77 V / 26 dB / 1,4 V

Maximum input level

21 dBV / 9 V

Input impedance, active balanced

20 kΩ

Signal/noise ratio, A-weighted, RMS

> 80 dB

> 85 dB

Cross-talk @ power rating, 8 Ω, 1 kHz

> 70 dB

Damping factor, f=1 kHz, 8 Ω

> 150 dB

Slew rate

35 V/µS

40 V/µS

Protection circuits

Current limit with short circuit, DC voltage fault, 

fuse for supply voltage, limiter, temperature, mains 

power transients

Slow Start

Control indicators

Power (green), protection circuit (yellow),

 

clipping (red), bridged operation (green),

 

parallel operation (green)

Cooling

fanless

Power consumption with half power, 8 Ω

65 W

100 W

120 W

Supply voltage

115 V / 230 V, 50-60 Hz

Dimensions (W x D x H) in mm

483 x 250 x 44 483 x 250 x 44

483 x 270 x 88

Our products are subject to a process of continual further development. Therefore modifications to 

the technical features remain subject to change without further notice.

Contact:

Musikhaus Thomann • Treppendorf 30 • 96138 Burgebrach • Germany

www.thomann.de

Summary of Contents for S- 75

Page 1: ...S 75 S 100 S 150...

Page 2: ...llel and bridged operations are possible X X Speaker outputs for Speakon and terminals X X Contents Device features 2 1 Introduction 3 2 Notes on safety 4 3 Becoming acquainted with the operational co...

Page 3: ...ction We are pleased by your purchase and are proud of the long tradition of quality high class devices for which our company stands In order to get the best out of your amplifier you should read the...

Page 4: ...used for a long time for example during holidays Always grasp the power cord by the plug Do not pull on the cord itself and never touch the power cord with wet hands as this could result in a short c...

Page 5: ...clockwise w CH 1 Input level controller for channel 1 With this controller you decrease the input level in channel 1 to the respective dB value indicated on the scale At the right end stop the attenua...

Page 6: ...re is a malfunction in the device y BR Indicator for bridged mono operation In this case amplify both channels together with the signal at input 1 This leads to a significantly higher single channel o...

Page 7: ...herefore keep the package and all packaging materials for their inspection You should keep the package and packaging materials even if no damage is present Should you need at some time to ship the dev...

Page 8: ...tion to the devices If the electrical outlets appear for example corroded or have rusted contacts or they are equipped with cables that are too thin this will affect the performance ability of the dev...

Page 9: ...e sure that the mains voltage switch located on the underside of the device resp rearside for S 150 is in the position that corresponds to the actual mains voltage supply in Germany 230V If in doubt a...

Page 10: ...nel CH 2 Speaker Pole channel CH 1 When in operation you control the volume only with the input level controller CH 1 w the input level controller CH 2 r then has no function The input signal from cha...

Page 11: ...ion provisions you must also as the operator of this device always keep in mind the limits of the speakers Make sure that you never exceed the load limit of the connected speaker with the power from y...

Page 12: ...S Protection circuits Current limit with short circuit DC voltage fault fuse for supply voltage limiter temperature mains power transients Slow Start Control indicators Power green protection circuit...

Reviews: