41
Problem:
No output signal at the loudspeakers;
the LEDs above the
and
buttons
flash
alternately
(the
PROTECTION circuit has tripped).
Cause 1:
The PROTECTION circuit has tripped due
to overheating or overloading.
Remedy:
Reduce volume and wait for about
20 seconds. If the unit does not switch on
again automatically, it has become too hot
and should be left switched off for a few
minutes to cool down.
Cause 2:
Short-circuit in the speaker leads, e. g.
stray wire ends touching at the speaker
terminals, or mechanical damage to the
cables.
Remedy:
Check speaker leads and terminals, twist
wire
ends
together
neatly,
replace
damaged cables.
Cause 3:
Overloading due to poor earth contact.
Remedy:
Disconnect input cable and wait to see if
the amplifier switches back on again; if so,
check the input lead and replace if
necessary.
Problem:
Unit switches off repeatedly at fairly
high volume levels.
Cause 1:
Overheating due to heat build-up.
Remedy:
Set up the unit in such a way that an
unobstructed flow of cooling air is
guaranteed.
Cause 2:
Overheating
through
insufficient
loudspeaker impedance.
Remedy:
Use only loudspeakers of at least 4
Ω
impedance (DIN rating). That means a
minimum impedance of > 3.2
Ω
.
Problem:
Flat sound image, insufficient bass
response.
Cause:
The loudspeaker cables are connected
with reversed polarity.
Remedy:
Check the speaker connections at the
loudspeakers and at the amplifier’s
speaker terminals; correct if necessary.
Summary of Contents for P 1230 R
Page 2: ...2 ...
Page 6: ...6 Bedienelemente an der Frontseite P 1230 R PA 1230 R PA 1530 R ...
Page 14: ...14 Anschlusselemente P 1230 R PA 1230 R PA 1530 R ...
Page 26: ...26 Front panel controls P 1230 R PA 1230 R PA 1530 R ...
Page 34: ...34 Back panel connections P 1230 R PA 1230 R PA 1530 R ...
Page 46: ...46 Eléments de commande à l avant P 1230 R PA 1230 R PA 1530 R ...
Page 54: ...54 Eléments de raccordement P 1230 R PA 1230 R PA 1530 R ...
Page 68: ... elektroakustik GmbH Co KG Herford Deutschland Germany Allemagne ...