of different phases of the motor when using sine wave drive and the default value is 0.
When C2 setting is 0, indicating that the used Quantum motor phase is an ordinary one.
When the setting is a certain value, indicating a particular motor phase is used. C2 setting
range is 0-1, press
button
(UP)
or
button (
DOWN
) for selection.
After finishing C2 parameter setting, press
button (
SW
) to save the current
value and then press
button (
DOWN
) to enter C3 parameter setting interface.
○
C3
Power Assist Ratio Gear Initialization Setting
Enter C3 parameter setting interface after C2 parameter setting is finished, press
button (
SW
), C3 parameter column flashes.
C3 parameter setting interface
Press
button
(UP)
or
button
(DOWN)
for selection C3 parameter values.
The factory default is 8.
C3 parameter values
:
C3
Parameter value meaning
0
The meter is powered on and the power assist ratio is at gear 0.
1
The meter is powered on and the power assist ratio is at gear 1.
2
The meter is powered on and the power assist ratio is at gear 2.