![SZKTDZ KT-LCD4 User Manual Download Page 25](http://html1.mh-extra.com/html/szktdz/kt-lcd4/kt-lcd4_user-manual_1423882025.webp)
ELECTRIC BICYCLE METER KT
—
LCD4 Product User Manual
- 23 -
Enter P5 parameter setting interface after P4 parameter setting is finished,
press
button,
P5 parameter column flashes.
P5 parameter setting interface
P5 is power monitoring setting, when P5 setting is 0, the power monitoring is the
"
real-time voltage
" mode. Namely, it is the method to determine the battery capacity
based on real-time battery voltage. When P5 equals to a specified parameter, the power
monitoring is the "
smart power
" mode (this parameter is determined by the battery
characteristics, ordinary 24V lithium is generally is 4-11, 36V lithium is between 5_15). P5
setting ranges from 0-40, press
button (
UP
) or
button
(DOWN)
for selection.
P5 parameter setting method is the same to that of P2.
After finishing P5 parameter setting, press
button (
SW
) to save the current
values, and then P5 parameter column stops flashing. Hold
button (
SW
) for about 2
seconds to save & exit P parameter setting environment and return to the display 1.
○
Exit P Parameter Setting
Among the five P parameter settings, when each parameter setting is completed, if
held
button (
SW
) long for about 2 seconds, all can exit the setting environment and
return to display 1, meanwhile, the current set parameters would be saved.