VR 250 ECH/B 

 

Operation and maintenance instructions 

 
206610 (16-11-2010) 

7

 Systemair 

AB 

   GB 

Maintenance 

 

 

 

 

 

 

 

Fig. 3 

Fig. 4 

 
Maintenance of the VR 250 ECH/B should normally be performed 3 - 6 times a year. Apart from general 
cleaning the following should be observed: 

Changing extract/inlet filter  

Changing extract/inlet filter (lamp signal on control panel) 1 - 2 times per year or as necessary 

(Fig. 3)

 

The bag filters cannot be cleaned and must be changed as necessary. (Contact your supplier for new 
filter). 
 
Operation time between filter changes must be re-set after filter change. Press button 13 

(fig. 2)

 for 

approx. 5 seconds. Yellow lamp (14) and one of the green lamps (6, 7 or 8, depending on chosen 
operation time) will flash for a few seconds. 
 

Each time a filter change is performed it is recommended to check the driving belt for the heat 
exchanger rotor. Check that the belt is undamaged and tight. Test that the drive belt wheel moves 
when the rotor is moved by hand. If the belt needs to be replaced contact your installer.

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

Fig. 5

 

Fig. 6 

Changing operation time between filter changes 

Depending on the condition of the filter, you might need to change the operation time for the filter. See 
Installation instructions - "Commissioning". 

Summary of Contents for VR-250 ECH/B

Page 1: ...10 02 16 11 2010 VR 250 ECH B Air Handling Unit Operation and maintenance instructions GB GB...

Page 2: ...operation 5 Manual summer operation 5 Kitchen extraction 6 Maintenance 7 Changing extract inlet filter 7 Changing operation time between filter changes 7 Checking the heat exchanger 8 Checking the fa...

Page 3: ...ply of filtered and preheated outdoor air to residential areas and extract of a corresponding amount of used air from wet rooms and kitchen The unit is equipped with a heat exchanger block to ensure s...

Page 4: ...hange Signal heater battery ON Fig 2 The unit is controlled from a separate controller with the following functions Airflow Fan speed Buttons to increase or decrease airflow in 3 steps 4 and 5 fig 2 L...

Page 5: ...ated but the efficiency will be reduced if the filter is not replaced Operation time 6 9 or 12 months between filter changes can be set on the control panel see installation instructions From factory...

Page 6: ...cooker is led directly through the extract fan and not through the heat exchanger The capacity of the extract fan is then primarily used for extract from the cooker but a minor airflow is maintained...

Page 7: ...y Contact your supplier for new filter Operation time between filter changes must be re set after filter change Press button 13 fig 2 for approx 5 seconds Yellow lamp 14 and one of the green lamps 6 7...

Page 8: ...sary the fans can be pulled out for cleaning with a soft brush Do not use water White spirit can be used to remove obstinate settlements Allow to dry properly before remounting Cleaning extract louver...

Page 9: ...pulling out the plug for 20 30 seconds 4 Cold supply air a Check set supply air temperature on the control panel b Check if fire thermostat is still alert If necessary reset by pressing the red butto...

Page 10: ...nintended rotor stop belt breakage defective motor 1 1 Missing zero crossing detector 1 1 Voltage too low 210 V Lamps 6 7 and 8 are flashing in accordance with set inlet air temperatures see Operation...

Page 11: ...10 02 Systemair AB Industriv gen 3 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com 206610 16 11 2010...

Reviews: