VR 250 ECH/B 

 

Operation and maintenance instructions 

 
206610 (16-11-2010) 

4

 Systemair 

AB 

   GB 

Operation 

 

 

 

 

 

 
 
 



 Signal 

airflow

 

 



   

Switches airflow

 

 



 

Signal supply air temperature

 

 

   

Switches supply air temperature

 

 

 

 

Signal filter change

 

 

 

 

Signal summer operation

 

 

 

 

Reset of operation time after filter change 

 

 

 

Signal heater battery ON 

 

Fig. 2   

 
The unit is controlled from a separate controller, with the following functions: 

Airflow (Fan speed) 

Buttons to increase or decrease airflow in 3 steps (4) and (5) 

(fig.2)

. Lamp signals (1), (2) and (3) show 

set airflow. 
 
Min(1)

 

Minimum ventilation.  
To be used during holidays or when the building is not in use.

 

Norm(2)

 

Normal ventilation adapted to the building.  
Airflow for normal ventilation can be chosen by means of a potentiometer on the main print 
card (see installation instructions-Commissioning).

 

Max(3)

 

Forced ventilation.  
Is used when extra airflow is required. 

 

Summary of Contents for VR-250 ECH/B

Page 1: ...10 02 16 11 2010 VR 250 ECH B Air Handling Unit Operation and maintenance instructions GB GB...

Page 2: ...operation 5 Manual summer operation 5 Kitchen extraction 6 Maintenance 7 Changing extract inlet filter 7 Changing operation time between filter changes 7 Checking the heat exchanger 8 Checking the fa...

Page 3: ...ply of filtered and preheated outdoor air to residential areas and extract of a corresponding amount of used air from wet rooms and kitchen The unit is equipped with a heat exchanger block to ensure s...

Page 4: ...hange Signal heater battery ON Fig 2 The unit is controlled from a separate controller with the following functions Airflow Fan speed Buttons to increase or decrease airflow in 3 steps 4 and 5 fig 2 L...

Page 5: ...ated but the efficiency will be reduced if the filter is not replaced Operation time 6 9 or 12 months between filter changes can be set on the control panel see installation instructions From factory...

Page 6: ...cooker is led directly through the extract fan and not through the heat exchanger The capacity of the extract fan is then primarily used for extract from the cooker but a minor airflow is maintained...

Page 7: ...y Contact your supplier for new filter Operation time between filter changes must be re set after filter change Press button 13 fig 2 for approx 5 seconds Yellow lamp 14 and one of the green lamps 6 7...

Page 8: ...sary the fans can be pulled out for cleaning with a soft brush Do not use water White spirit can be used to remove obstinate settlements Allow to dry properly before remounting Cleaning extract louver...

Page 9: ...pulling out the plug for 20 30 seconds 4 Cold supply air a Check set supply air temperature on the control panel b Check if fire thermostat is still alert If necessary reset by pressing the red butto...

Page 10: ...nintended rotor stop belt breakage defective motor 1 1 Missing zero crossing detector 1 1 Voltage too low 210 V Lamps 6 7 and 8 are flashing in accordance with set inlet air temperatures see Operation...

Page 11: ...10 02 Systemair AB Industriv gen 3 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com 206610 16 11 2010...