background image

4

Product information

4.2

Technical data

4.2.1

Dimensions

A

B

E

C

D

ø

F

Fig. 1 KVK Slim

Model

A

B

C

D

E

øF

KVK Slim 200 EC

620

542

513

415

270

200

KVK Slim 200

620

542

513

415

270

200

KVK Slim 250 EC

773

657

548

450

300

250

KVK Slim 250

773

657

548

450

300

250

KVK Slim 315

945

825

694

590

451

315

KVK Slim 315 EC

866

746

694

590

414

315

KVK Slim 355

961

842

870

766

496

355

KVK Slim 355 EC

976

842

770

666

459

355

KVK Slim 400

1001

842

870

766

496

400

KVK Slim 400 EC

1001

842

770

666

459

400

KVK Slim 500 EC

1213

1055

873

768

605

500

KVK Slim 500

1213

1055

873

768

605

500

145899 | A007

Summary of Contents for KVK Silent 200

Page 1: ...Document in original language 145899 A007 KVK Slim 200 500 KVK Slim 200 500 EC KVK Silent 200 500 KVK Silent 200 500 EC Operation and Maintenance Instructions GB...

Page 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Page 3: ...ormation 3 4 1 General 3 4 2 Technical data 4 4 2 1 Dimensions 4 4 2 2 Performance 6 4 2 3 Wiring diagram 8 4 3 Transportation and storage 9 5 Installation 9 5 1 Commissioning 10 6 Maintenance 10 6 1...

Page 4: ......

Page 5: ...g reached by upper or lower limbs EN 60 335 1 Household and similar electrical appliances Safety Part 1 General requirements EN 60 335 2 80 Household and similar electrical appliances Safety Part 2 80...

Page 6: ...ental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children sha...

Page 7: ...ilent 200 500 KVK Silent 200 500 EC are intended for transporta tion of air in air handling systems The fans are meant for use in ducted systems and should always be duct connected on the inlet side N...

Page 8: ...0 EC 773 657 548 450 300 250 KVK Slim 250 773 657 548 450 300 250 KVK Slim 315 945 825 694 590 451 315 KVK Slim 315 EC 866 746 694 590 414 315 KVK Slim 355 961 842 870 766 496 355 KVK Slim 355 EC 976...

Page 9: ...250 836 720 630 533 382 250 872 KVK Silent 315 1022 906 768 672 536 315 1165 KVK Silent 315 EC 946 826 768 672 493 315 1125 KVK Silent 355 1041 922 952 848 578 355 1383 KVK Silent 355 EC 1041 922 852...

Page 10: ...s Pa 19706 19705 4 6V 10V KVK Silent 200 EC 2 6V 6 6V 0 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 0 500 1000 1500 m h Q m s Ps Pa 19730 19729 4 6V 6 8V 10V KVK Slim 250 EC 2 4V 0 0 1 0 2 0 3 0 4 0 5 0...

Page 11: ...Q m s Ps Pa 19037 19036 4 7V 6 9V 10V KVK Silent 400 EC 2 4V 0 0 5 1 1 5 2 0 200 400 600 0 2000 4000 6000 m h Q m s Ps Pa 19249 19244 19243 5V 7 2V 10 KVK Slim 500 EC 2 5V 0 0 5 1 1 5 2 0 200 400 600...

Page 12: ...250 315 Slim Silent GY GY BN BU BK YE GN TK TK N L C Fig 4 KVK 355 500 Slim Silent RD YE BU WH BU BK YE GN 10V GND Tacho 0 10V N L Fig 5 KVK 200 250 Slim Silent EC RD YE BU WH BN WH WH BU BK YE GN 10...

Page 13: ...rried out by an authorized installer and in accordance with local rules and regulations Warning The units electrical connection to the mains supply must be preceded by an all pole circuit breaker with...

Page 14: ...sure that the mains supply to the unit is disconnected before performing any maintenance or electrical work Fan impeller has come to a complete standstill Should the supply cable be damaged it must b...

Page 15: ...e fan not start please contact your place of purchase 8 Deinstallation dismantling Deinstall and dismantle the fan in reverse order of installation and electrical connection 9 Disposal Ensure material...

Page 16: ...KVK Silent 200 500 KVK Silent 200 500 EC Operation and Maintenance Instructions 145899 en_GB 2019 03 15 A007 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00...

Reviews: