background image

Declaration of conformity |

1

1

Declaration of conformity

Manufacturer

Systemair Sverige AB
Industrivägen 3
SE-739 30 Skinnskatteberg SWEDEN
Office: +46 222 440 00 Fax: +46 222 440 99
www.systemair.com

hereby confirms that the following products:

KVK Slim 200–500, KVK Slim 200–500 EC, KVK Silent 200–500, KVK Silent 200–500 EC

(The declaration applies only to product in the condition it was delivered in and installed in the facility in accordance with the included installation in-
structions. The insurance does not cover components that are added or actions carried out subsequently on the product)

Comply with all applicable requirements in the following directives and regulations

Machinery Directive 2006/42/EC

Ecodesign Directive 2009/125/EC

327/2011 Requirements for fans
1253/2014 Requirements for ventilation units

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU

(Residential units)

The following harmonized standards are applied in applicable parts:

EN ISO 12100

Safety of machinery – General principles for design – Risk assessment and risk reduction.

EN 13857

Safety of machinery – Safety distances to prevent hazard zones being reached by upper or lower limbs.

EN 60 335-1

Household and similar electrical appliances – Safety Part 1: General requirements.

EN 60 335-2-80

Household and similar electrical appliances – Safety – Part 2-80: Particular requirements for fans.

EN 62233

Measurement methods for electromagnetic fields of household appliances and similar apparatus with
regard to human exposure.

EN 50 106

Safety of household and similar appliances – Particular rules for routine tests referring to appliances under
the scope of EN 60 335-1 and EN 60967.

EN 60529

Degrees of protection provided by enclosures (IP Code).

EN 60 204-1

Safety of machinery – Electrical equipment of machines – Part 1: General requirements

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments.

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standards for residential,
commercial and light-industrial environments.

EN ISO 5801

Fans – Performance testing using standardized airways

EN 13142

Ventilation for buildings – Components/products for residential ventilation – Required and optional
performance characteristics.

EN 14121

Aluminium and aluminium alloys – Sheet, strip and plate for electrotechnical applications.

The complete technical documentation is available.

Skinnskatteberg, 2019-03-15

Mats Sándor
Technical Director

145899 | A007

Summary of Contents for KVK Silent 200

Page 1: ...Document in original language 145899 A007 KVK Slim 200 500 KVK Slim 200 500 EC KVK Silent 200 500 KVK Silent 200 500 EC Operation and Maintenance Instructions GB...

Page 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Page 3: ...ormation 3 4 1 General 3 4 2 Technical data 4 4 2 1 Dimensions 4 4 2 2 Performance 6 4 2 3 Wiring diagram 8 4 3 Transportation and storage 9 5 Installation 9 5 1 Commissioning 10 6 Maintenance 10 6 1...

Page 4: ......

Page 5: ...g reached by upper or lower limbs EN 60 335 1 Household and similar electrical appliances Safety Part 1 General requirements EN 60 335 2 80 Household and similar electrical appliances Safety Part 2 80...

Page 6: ...ental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children sha...

Page 7: ...ilent 200 500 KVK Silent 200 500 EC are intended for transporta tion of air in air handling systems The fans are meant for use in ducted systems and should always be duct connected on the inlet side N...

Page 8: ...0 EC 773 657 548 450 300 250 KVK Slim 250 773 657 548 450 300 250 KVK Slim 315 945 825 694 590 451 315 KVK Slim 315 EC 866 746 694 590 414 315 KVK Slim 355 961 842 870 766 496 355 KVK Slim 355 EC 976...

Page 9: ...250 836 720 630 533 382 250 872 KVK Silent 315 1022 906 768 672 536 315 1165 KVK Silent 315 EC 946 826 768 672 493 315 1125 KVK Silent 355 1041 922 952 848 578 355 1383 KVK Silent 355 EC 1041 922 852...

Page 10: ...s Pa 19706 19705 4 6V 10V KVK Silent 200 EC 2 6V 6 6V 0 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 0 500 1000 1500 m h Q m s Ps Pa 19730 19729 4 6V 6 8V 10V KVK Slim 250 EC 2 4V 0 0 1 0 2 0 3 0 4 0 5 0...

Page 11: ...Q m s Ps Pa 19037 19036 4 7V 6 9V 10V KVK Silent 400 EC 2 4V 0 0 5 1 1 5 2 0 200 400 600 0 2000 4000 6000 m h Q m s Ps Pa 19249 19244 19243 5V 7 2V 10 KVK Slim 500 EC 2 5V 0 0 5 1 1 5 2 0 200 400 600...

Page 12: ...250 315 Slim Silent GY GY BN BU BK YE GN TK TK N L C Fig 4 KVK 355 500 Slim Silent RD YE BU WH BU BK YE GN 10V GND Tacho 0 10V N L Fig 5 KVK 200 250 Slim Silent EC RD YE BU WH BN WH WH BU BK YE GN 10...

Page 13: ...rried out by an authorized installer and in accordance with local rules and regulations Warning The units electrical connection to the mains supply must be preceded by an all pole circuit breaker with...

Page 14: ...sure that the mains supply to the unit is disconnected before performing any maintenance or electrical work Fan impeller has come to a complete standstill Should the supply cable be damaged it must b...

Page 15: ...e fan not start please contact your place of purchase 8 Deinstallation dismantling Deinstall and dismantle the fan in reverse order of installation and electrical connection 9 Disposal Ensure material...

Page 16: ...KVK Silent 200 500 KVK Silent 200 500 EC Operation and Maintenance Instructions 145899 en_GB 2019 03 15 A007 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00...

Reviews: