background image

Operating instructions

K3G097-AK34-62

MOBILE CLIMATE CONTROL
P/N 54-00627-07

Translation of the original operating instructions

ebm-papst Mulfingen GmbH & Co. KG

Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
[email protected]
www.ebmpapst.com

CONTENTS

1. SAFETY REGULATIONS AND INFORMATION

1

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.

1.1 Hazard levels for warnings

1

1.1 Hazard levels for warnings

These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:

DANGER

Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.

WARNING

Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.

CAUTION

Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.

NOTE

A potentially harmful situation can occur and, if not avoided, can
lead to property damage.

1.2 Staff qualifications

1

1.2 Staff qualifications

The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by suitably qualified, trained and
authorized technical staff.
Only authorized specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.

1.3 Basic safety rules

1

1.3 Basic safety rules

The safety hazards associated with the device must be assessed again
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:

;

Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

WARNING

To reduce the risk of fire, electric shock or injury to people, do
not use any replacement or add-on parts that have not been
approved by ebm-papst (e.g. parts manufactured with a 3D
printer).

2

1.4 Voltage

2

1.5 Safety and protective features

2

1.6 Electromagnetic radiation

2

1.7 Mechanical movement

2

1.8 Emissions

2

1.9 Hot surface

2

1.10 Transport

2

1.11 Storage

3

2. INTENDED USE

4

3. TECHNICAL DATA

4

3.1 Product drawing

5

3.2 Nominal data

5

3.3 Technical description

5

3.4 Mounting data

5

3.5 Transport and storage conditions

6

4. CONNECTION AND STARTUP

6

4.1 Mechanical connection

6

4.2 Electrical connection

7

4.3 Connection diagram

8

4.4 Checking connections

8

4.5 Switching on the device

8

4.6 Switching off the device

8

5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES

9

5.1 Cleaning

9

5.2 Safety inspection

9

5.3 Disposal

Item no. 56626-5-9970 · ENU · Change 234450 · Approved 2022-09-06 · Page 1 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Downloaded from

Arrow.com.

Summary of Contents for K3G097-AK34-62

Page 1: ...be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to...

Page 2: ...ller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing j...

Page 3: ...uld be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to th...

Page 4: ...able PVC FLRY B 2x 2 5 mm FLRY B 2x 0 75 mm 4x wire end ferrule Insulating sleeve PVC dia 8 mm 2 Nameplate 3 Warning label yellow background black print Item no 56626 5 9970 ENU Change 234450 Approved...

Page 5: ...III Requires supply with safety extra low voltage SELV This component for installation may have several local protection classes This information relates to this component s basic design The final pro...

Page 6: ...until all fastening screws have been tightened The fan must not be strained on fastening 4 2 Electrical connection CAUTION Voltage The fan is a built in component and has no disconnecting switch Only...

Page 7: ...t 1 1 1 UB black Power supply 2 1 2 GND brown Power supply GND reference ground 3 1 3 PWM LIN yellow Analog voltage control input 0 10 V or PWM 4 1 4 DIAG white Diagnostic output Item no 56626 5 9970...

Page 8: ...maintenance Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTI...

Page 9: ...corporate goals ebm papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right...

Page 10: ...ents employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 56626 5 9970 ENU Change 234450 Approved 2022 09 06 Page 10 10 ebm papst M...

Reviews: