SystemAir KD 300F EC Installation And Maintenance Manual Download Page 2

2

Before installation, servicing or cleaning unit, switch power 

off at service panel and lock the service disconnecting 

means to prevent power from being switched on 

accidentally. When the service disconnecting means cannot 

be locked, securely fasten a prominent warning device, 

such as a tag, to the service panel.

1. The compactness and adaptability of the KD Series fans 

permit easy installation. The fans are shipped fully 
assembled and can be mounted at any angle. For various 
mounting, see figures on the following page.

2. Because this unit has rotating parts, safety precautions 

should be exercised during all phases of installation, 
operation and maintenance.

3. CAUTION: “For General Ventilation Use Only. Do Not Use 

To Exhaust Hazardous Or Explosive Material and Vapors.”

  For indoor installation only.

4. Remove unit from package and inspect within 15 days 

after receipt. If damaged, report damage to carrier. Do 
Not operate this unit with visible damage to the blower or 
impeller assembly.

5. 

CAUTION:

 “This unit has an unguarded impeller. Do not 

use in locations readily accessible to people or animals.”

WEAR HAND PROTECTION AND STAY CLEAR OF SHARP 

EDGES! 

6. Screen guards must be installed within reach of 

personnel, within (7) feet of the working area, or when 
advisable for safety.

7.

 PLEASE 

read the entire manual before installing.

DO NOT CONNECT POWER SUPPLY until fan is completely 

installed. Make sure electrical service to the fan is in the 

locked “OFF” position.

1. All fans are suitable for use with solid-state speed control. 

Three phase units must be wired through a motor 
contactor.

2. 

WARNING! 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 

OR INJURY TO PERSONS - OBSERVE THE FOLLOWING:

a. Use this unit in the manner intended by the manufacturer. 

If you have any questions, contact your manufacturer’s 
representative or contact us directly.

b. 

CAUTION:

 Before installation, servicing or cleaning unit, 

switch power off at service panel and lock the service 
disconnection means to prevent power from being 
switched on accidentally. When the service disconnection 
means cannot be locked, securely fasten a prominent 
warning device, such as tag, to the panel.

c. Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction.

d. Sufficient air is needed for proper combustion and 

exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent back drafting. Follow the 
heating equipment manufacturer’s guideline and safety 
standards such as those published by the National Fire 
Association (NFPA), and the American Society for Heating, 
Refrigeration and Air-Conditioning Engineers (ASHRAE), 
and the local code authorities.

e. When cutting or drilling into wall and ceiling, do not 

damage electrical wiring and other hidden utilities.

f. Ducted fans must always be vented to the outdoors.
g. If this unit is to be installed over a tub or shower, it must 

be marked as appropriate for the application and be 
connected to a GFCI (Ground Fault Circuit Interrupter) - 
protected branch circuit.

h. 

NEVER

 place a switch where it can be reached from a tub 

or shower.

3. 

WARNING! 

Check voltage at the fan to see if it 

corresponds to the motor name plate.

Important safety information

Warnings

Warning

Summary of Contents for KD 300F EC

Page 1: ...am Systemair Inc certifie que les ventilateurs de la s rie KD EC d crits aux pr sentes portent le sceau de l ACMA Les caract ristiques indiqu es sont fond es sur les essais et proc dures effectu s con...

Page 2: ...ts must be wired through a motor contactor 2 WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit in the manner intended by the manufacturer If...

Page 3: ...king at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use...

Page 4: ...utilis s avec une commande de vitesse Les appareils avec trois vitesses doivent tre reli s un interrupteur et un disjoncteur 2 AVERTISSEMENTS POUR R DUIRE LES RISQUES D INCENDIE DE D CHARGE LECTRIQUE...

Page 5: ...s sur la cuisini re que s ils sont n cessaires Faites chauffer l huile lentement feu bas ou mod r D Ne laissez pas la cuisini re sans surveillance pendant la cuisson E Utilisez toujours une batterie d...

Page 6: ...nidades trif sicas tienen que cablearse a trav s de un contactor de motores 2 ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO CONMOCION ELECTRICA O LESIONES A PERSONAS OBSERVE LO SIGUIENTE a S lo utili...

Page 7: ...ule el grado de calor de la estufa solamente cuando es necesario Caliente aceites lentamente poniendo el grado de calor en mediano o bajo D No deje la estufa sin atender cuando hay algo cocinando E Si...

Page 8: ...ur complet chaque crochet R p tez cette proc dure jusqu ce que les supports temporaires soient l ches et que le chargement de la tuyauterie ou l quipement soit suspendu compl tement sur les crochets d...

Page 9: ...t quip de support de vibration attachez les aux supports 3 Attachez le ventilateur aux supports de vibration fourni par d autres veillez ne pas trop serrer l l ment de n opr ne 4 Si le ventilateur est...

Page 10: ...m me moment 5 Voir le chapitre sur l installation lectrique pour terminer l installation Les Supports de vibration et le mat riel ne sont pas inclus avec le ventilateur FK adents de serrage sont vend...

Page 11: ...12 14 201 4 177 8 187 8 7 8 4 83 4 3 8 38 KD 355F EC 14 14 16 221 8 193 4 201 4 1 1 2 4 8 3 4 3 8 45 KD 400E EC 16 14 16 221 8 193 4 183 4 1 1 2 4 71 8 3 8 75 KD 400D EC 16 16 18 243 8 221 8 233 4 1 1...

Page 12: ...0V potentiometer Terminals D1 24V Elec tronic ON OFF control via floating contact Factory installed jumper wire Bornes 11 14 Indicateur de d faut externe 250V 2A max Bornes GND E1 10V Borne de control...

Page 13: ...nstallation for any breach of warranty WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an a...

Page 14: ...un d faut d usine en mati re de qualit d ex cution ou de mat riau Il sera peut tre n cessaire de retourner le produit l usine Systemair accompagn d une copie du contrat de vente et du num ro d autori...

Page 15: ...ci n o reinstalaci n por incumplimiento de la garant a VALIDACI N DE LA GARANT A El usuario debe conservar una copia de la constancia de com praventa para verificar la fecha de compra Estas garant as...

Page 16: ...Systemair Inc 10048 Industrial Blvd Lenexa KS USA 66215 www systemair net 409007 2016 11 22...

Reviews: