5.5
AXCBF-EX series / AXC-EX axial fans
5.5.1
Types
AXCBF-EX 250
AXCBF-EX 400
AXCBF-EX 315
AXCBF-EX 500
AXCBF-EX 630
AXCBF-EX 800
AXC-EX 355 ... AXC-EX 1600
5.5.2 Description
•
Aerodynamic rotor
•
Hub and blades of aluminium die cast
•
Housing hot-galvanised steel to DIN EN ISO 1461
•
Aluminium slip ring
•
Seamed flanges to Eurovent standard ½ for high rigidity
•
Three-phase motors, IP55, insulation class F, according to EN 60034, IEC 85.
•
Admissible ambient temperatures from -20°C to max. 60°C, see Table 6.
•
AXC-EX: supplied with Ex e connection box on the outside of the housing
•
AXCBF-EX: motor outside the air flow
The divided medium-pressure axial fans of the AXCBF-EX / AXC-EX series are available with rotor diameters from 250
to 1600 mm.
They can be used for temperature classes T1, T2, T3 and T4. They convey explosion-capable gases in Zone 1 and Zone
2 as well as groups IIA, IIB and IIC.
Ex d: The motor has motor protection through an integrated posistor (PTC) and is speed-variable through a frequency
converter.
For temperatures above +40 °C, the maximum motor load according to the following table is to be considered:
Description
48