INSTALLATION
The cooker hood is intended for installation
built into cupboards. The cooker hood is
equipped with a motorised damper, LED
lamps and metal mesh filter. Installation,
use, care, maintenance etc., are described
in these instructions.
TECHNICAL INFORMATION
Fig. 1
Measurements
see Fig. 1
Electrical
installation
230 V ~ earthed.
Lighting
LED 2 x 2 W
Output voltage
from transformer
60, 80, 100, 130,
145 and 180 V.
At the time of deli-
very, 80 V and 130
V are connected.
INSTALLATION
Fixing parts, screws for mounting, etc. are
supplied with the cooker hood.
Electrical installation with quick
connectors
The central fan and cooker hood are both
equipped with a control cable and pluggab-
le terminal block. The cooker hood is also
fitted with an electrical cable and earthed
plug for connection to an earthed wall sock-
et, 10A/230V.
Refer to he instructions included for electri-
cal installation with an extension cable.
Fixed connection without an extension
cable and pluggable terminal block.
Remove the pluggable terminal block and
plug. Connect the cooker hood and central
fan using a terminal block.
Fixed installation or replacement of cables
must be performed by a tradesman. The
cooker hood must be preceded by an isola-
tor switch.
Attention!
The cooker hood is equipped with an
electronic motor control unit which, af-
ter being switched on, performs an auto-
matic self-test that takes around ten
seconds. During this time, the control
panel must not be used.
Installing the damper.
Fig. 2
A duct connector with damper is provided
inside the hood.
16