background image

HOOD

E-220 

INSTALLATION GUIDE

 

660066400119

 

Summary of Contents for E-220

Page 1: ...HOOD E 220 INSTALLATION GUIDE 660066400119 ...

Page 2: ......

Page 3: ...2 50 m The included threaded rods allow a height adjustment of 187 to 340 mm The conduit must be Ø 150 mm connecting to the exhaust conduit it can be adapted to a Ø150 mm circular rigid conduit or optionally it can be connected to a rectangular adaptor measuring 100x180 mm to Ø150 mm round As standard it comes with the outlet on the short side Optionally you can order it with the outlet on the lon...

Page 4: ...ON SHORT SIDE OUTLET ON LONG SIDE STANDARD ORIFICE FOR HOOD ORIFICE FOR SPECIAL ORDER HOOD NOTE 500 x 500 area reserved for connecting the hood tubes close the false ceiling when installed This model is supplied with threaded rods These are screwed into the ceiling structure Nuts are used to adjust the height of the hood 187 mm 340 mm Make 4 holes in the ceiling according to the dimensions indicat...

Page 5: ...exible conduit If on taking it out it projects more than 30 cm the surplus should be cut off and removed so as to avoid undesired bends in the conduit installation Install the accessory supplied with the hood to convert the rectangular 100 x 180 section to Ø150 And prepare the mains cable for connection WARNING To avoid air leaks or the conduit detaching make sure the joints of the conduit with th...

Page 6: ...ring that the threaded rods enter their holes The external edge of the hood should coincide perfectly with the false ceiling Fit the washers and nuts supplied with the hood to threaded rods making sure they are properly tightened and Wing nuts and washers turn the wing nut until you obtain the desired height taking into account that the bezel of the hood should be flush with the false ceiling at t...

Page 7: ...il the installation is completely finished WARNING Before connecting to the mains make sure the socket is not live It should be Once it is connected test in operation looking for air leaks if everything is Ok close the 500 x 500 false ceiling With the hatch open you can see the on off switch of the hood If all the connections have been made proceed to start it up WARNING Once in operation follow t...

Page 8: ...operation of this model it is necessary to have ventilation grilles at floor level for continuous admission of air The maximum distance from the FLOOR to the FALSE CEILING must not be greater than 2 5 m IMPORTANT For optimum aspiration the hood should be centred over the cooking area ACCESSORIES INCLUDED The accessories are inside the hood 4 Threaded 8 mm rods 8 Washers Ø24mm 4 Washers Ø60mm 4 Nut...

Page 9: ... the remote control facing the hood Then the light will turn on the hood and it will confirm that synchronization was successful Light button Light button The remote control synchronization with hood can be lost due to not making the synchronization process well before 15 seconds after the switch on due to power outages or variations on the electrical network causing the hood doesn t respond to re...

Page 10: ...nufacturer supplies the remote control ready for use with the factory default codes If you want to generate new codes do the following Press simultaneously and keep pressed the three keys indicated in the illustration 1 2 3 until the LED 5 begins to flash at that moment the control is going through the different frequencies available when you release the keys the led 5 will stop flashing and recor...

Page 11: ......

Page 12: ... Apdo Correos nº21 08310 ARGENTONA Barcelona Spain Tel 34 93 757 94 11 Fax 34 93 757 96 53 www pando es Com pando pando es Certificado de Empresa de Gestión de la Calidad UNE EN ISO 9001 2008 The International Certification Network Quality Management System ISO 9001 2008 ...