THREE-YEAR LIMITED WARRANTY

System Sensor warrants its enclosed smoke detector base to be free from 
defects in materials and workmanship under normal use and service for a 
period of three years from date of manufacture. System Sensor makes no 
other express warranty for this smoke detector base. No agent, represen-
tative, dealer, or employee of the Company has the authority to increase 
or alter the obligations or limitations of this Warranty. The Company’s 
obligation of this Warranty shall be limited to the repair or replacement 
of any part of the smoke detector base which is found to be defective 
in materials or workmanship under normal use and service during the 
three year period commencing with the date of manufacture. After phon-
ing System Sensor’s toll free number 800-SENSOR2 (736-7672) for a 
Return Authorization number, send defective units postage prepaid to: 
Honeywell, 12220 Rojas Drive, Suite 700, El Paso TX 79936, USA. Please 

include a note describing the malfunction and suspected cause of failure. 
The Company shall not be obligated to repair or replace units which are 
found to be defective because of damage, unreasonable use, modifica-
tions, or alterations occurring after the date of manufacture. In no case 
shall the Company be liable for any consequential or incidental damages 
for breach of this or any other Warranty, expressed or implied whatsoever, 
even if the loss or damage is caused by the Company’s negligence or fault. 
Some states do not allow the exclusion or limitation of incidental or con-
sequential damages, so the above limitation or exclusion may not apply to 
you. This Warranty gives you specific legal rights, and you may also have 
other rights which vary from state to state.

Please refer to insert for the Limitations of Fire Alarm Systems

  4 

I56-597-04R 

  

©2016 System Sensor. 06-10

firealarmresources.com

Summary of Contents for B112LP

Page 1: ...ative Humidity Noncondensing Electrical Ratings includes base and detector System Voltage 24 VDC Maximum Ripple Voltage 4 Volts peak to peak Start Up Capacitance 0 02µF Maximum Standby Ratings 20 VDC Minimum 29 VDC Maximum 120 µA Maximum Alarm Ratings 17 mA Minimum 36 mA Maximum Reset Voltage 1 4 VDC Minimum Reset Time 0 3 Seconds Maximum The optional RA400Z operates within specified detector alar...

Page 2: ...ach wire Slide the wires under the clamp plate and tighten the terminal screw If the base is being installed in a zoned system check the zone wiring before installing the smoke detector head The built in shorting spring makes it convenient to do this After the detector base is wired and attached to the electri cal box position the shorting spring against terminal 3 Use the slot in the retaining cl...

Page 3: ...N LOOP EOL RESISTOR EOL RELAY NOTE Schematic Shown for Reference 1 2 3 4 5 8 9 10 11 12 13 14 UL LISTED 4 WIRE CONTROL PANEL REMOTE ANNUNCIATOR RELEASING DEVICE OPTIONAL 1 2 3 4 5 8 9 10 11 12 13 14 REMOTE ANNUNCIATOR POWER LOOP POWER LOOP ALARM CIRCUIT RELEASING DEVICE OPTIONAL EOL RELAY RESISTOR EOL Figure 2 Typical wiring diagram Figure 3A Activating the tamper resistance feature PLASTIC LEVER ...

Page 4: ...rization number send defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modifica tions or alterations occurring after the date of manufacture In no ...

Reviews: