background image

DETECTOR

POWER LOOP

(+)

(–)

ALARM

INITIATION LOOP

FCI

CONTROL PANEL

ALARM RELAY

AUXILIARY CONTACTS

N.O.

12

N.C.

13

C.

14

(2.8 VDC)

(+)     (—)

1        4

ALARM

RELAY

REMOTE

ANNUNCIATOR

OUTPUT

(+IN)   2

3   (+OUT)

SPORTING

SPRING

5    (–IN, –OUT)

(IN)

10

(OUT)

11

ALARM RELAY

8

(IN)

9

(OUT)

FIRST DETECTOR IN LOOP

ALARM RELAY

AUXILIARY CONTACTS

N.O.

12

N.C.

13

C.

14

(2.8 VDC)

(+)     (—)

1        4

ALARM

RELAY

REMOTE

ANNUNCIATOR

OUTPUT

(+IN)   2

3   (+OUT)

SPORTING

SPRING

5    (–IN, –OUT)

(IN)

10

(OUT)

11

ALARM RELAY

8

(IN)

9

(OUT)

FIRST DETECTOR IN LOOP

EOL

RESISTOR

EOL RELAY

(+)

(–)

NOTE:  Schematic

 

Shown for

 

Reference

1

2

3

4

5

8 9

10

11

12

13

14

UL

 LISTED 4-WIRE CONTROL

 P

ANEL

REMOTE

ANNUNCIATOR

RELEASING

DEVICE

(OPTIONAL)

1

2

3

4

5

8 9

10

11

12

13

14

REMOTE

ANNUNCIATOR

POWER LOOP 

+

POWER LOOP –

ALARM CIRCUIT

RELEASING

DEVICE

(OPTIONAL)

EOL RELAY

RESIST

OR

+

+

+

EOL

Figure 2. Typical wiring diagram:

Figure 3A. Activating the tamper-resistance feature:

PLASTIC LEVER

BREAK TAB AT DOTTED LINE BY 

TWISTING TOWARD CENTER OF BASE

USE SMALL-BLADED SCREWDRIVER TO PUSH 

PLASTIC LEVER IN DIRECTION OF ARROW

Figure 3B. Removing detector head from base:

C0130-00

C0533-00

C0532-00

  

I56-597-04R 

 

 06-10

firealarmresources.com

Summary of Contents for B112LP

Page 1: ...ative Humidity Noncondensing Electrical Ratings includes base and detector System Voltage 24 VDC Maximum Ripple Voltage 4 Volts peak to peak Start Up Capacitance 0 02µF Maximum Standby Ratings 20 VDC Minimum 29 VDC Maximum 120 µA Maximum Alarm Ratings 17 mA Minimum 36 mA Maximum Reset Voltage 1 4 VDC Minimum Reset Time 0 3 Seconds Maximum The optional RA400Z operates within specified detector alar...

Page 2: ...ach wire Slide the wires under the clamp plate and tighten the terminal screw If the base is being installed in a zoned system check the zone wiring before installing the smoke detector head The built in shorting spring makes it convenient to do this After the detector base is wired and attached to the electri cal box position the shorting spring against terminal 3 Use the slot in the retaining cl...

Page 3: ...N LOOP EOL RESISTOR EOL RELAY NOTE Schematic Shown for Reference 1 2 3 4 5 8 9 10 11 12 13 14 UL LISTED 4 WIRE CONTROL PANEL REMOTE ANNUNCIATOR RELEASING DEVICE OPTIONAL 1 2 3 4 5 8 9 10 11 12 13 14 REMOTE ANNUNCIATOR POWER LOOP POWER LOOP ALARM CIRCUIT RELEASING DEVICE OPTIONAL EOL RELAY RESISTOR EOL Figure 2 Typical wiring diagram Figure 3A Activating the tamper resistance feature PLASTIC LEVER ...

Page 4: ...rization number send defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modifica tions or alterations occurring after the date of manufacture In no ...

Reviews: