sysmik Scalibur SCA-340 Manual Download Page 14

Installation and Commissioning 

14 

sysmik.de 

Manual SCA-340 / SCA-340-L

3.2 

Connections 

3.2.1 

Connectors 

 

1  Micro-SD card slot 

Switches for RS-485 termination / bias 

2  Type label with device-specific 

information 

Service interface 

3  Service button 

10 

Bus interface connector 

4  Ethernet (4x 10/100BaseT) 

11 

Supply connector 

5  FE connector *) 

12 

Labeling field (2x) 

6  USB 1 (mini USB, USB-OTG) 

13 

Diagnostic indicators 

7  USB 2 

14 

End plate 

*) … The FE connector is placed at the rear side of the connector – it is not visible in the 

sketch. 

Fig. 3.2.1.1:

 Overview device connections 

Summary of Contents for Scalibur SCA-340

Page 1: ...Rev 22 Scalibur Modular Controllers SCA 340 SCA 340 L Manual...

Page 2: ...warranties in case of improper use or disassembly and software modifications not described in this document or when using improper or faulty tools Commissioning and operation of the device by qualifie...

Page 3: ...Virtual Machine 9 2 2 5 Niagara Framework 10 3 Installation and Commissioning 11 3 1 Assembly 11 3 1 1 Dimensions 11 3 1 2 Mounting 12 3 1 3 Adding Inline Terminals 13 3 2 Connections 14 3 2 1 Connect...

Page 4: ...TP 30 4 2 Commissioning Scalibur 30 4 2 1 IP Addressing 31 4 2 2 Time and Time Zone 31 4 2 3 Hardware Data Point Test 31 4 3 Ethernet Switch for Flexible Network Topologies 33 4 3 1 Assignment of IP I...

Page 5: ...Commissioning Website is not accessible 48 5 3 2 IP Address unknown 48 5 3 3 No IP Communication 48 5 3 4 Unknown Niagara Platform Access Credentials 48 5 3 5 No Platform Connection to Device Platfor...

Page 6: ...s the Sedona framework in parallel to Niagara Sedona applications run with fixed cycle times in the millisecond range and are created with the Niagara Workbench Beside the separate exclusive use of ei...

Page 7: ...e extended with a microSD card 2 1 3 Ethernet The integrated Ethernet switch has 4 external ports which can be assigned independently to one of the two separate IP interfaces If at least two ports bel...

Page 8: ...space saving automation stations An Inline station consists of a bus controller and a set of IO terminals chosen freely in terms of numbers type and sequential arrangement The bus controller runs the...

Page 9: ...a an TCP connection This allows to control IOs remotely from another Niagara station The remote access can be limited or disabled by the setting of the IP address of the controlling station 2 2 3 Comm...

Page 10: ...a platform connection to the Niagara daemon This includes loading of software updates and of a station Niagara application which can be run automatically by the Niagara daemon A Workbench connection t...

Page 11: ...ioning Manual SCA 340 SCA 340 L sysmik de 11 3 Installation and Commissioning 3 1 Assembly 3 1 1 Dimensions Width x Height x Depth 80 mm x 119 8 mm x 71 5 mm 3 15 inch x 4 72 inch x 2 81 inch Fig 3 1...

Page 12: ...designed for easy snap in mounting on 35 mm x 7 5 mm DIN EN 60715 rails formerly DIN EN 50022 Note The DIN rail should be attached to a mounting plate or an even back plane for best stability Suitable...

Page 13: ...e keyways until they lock appropriately B2 Ensure that the feather keys are properly connected C2 C1 shows the common mistake that the feather keys are not inside their keyways After mounting all elec...

Page 14: ...device specific information 9 Service interface 3 Service button 10 Bus interface connector 4 Ethernet 4x 10 100BaseT 11 Supply connector 5 FE connector 12 Labeling field 2x 6 USB 1 mini USB USB OTG...

Page 15: ...onnecting the automation terminals please observe the derating of the logic voltage the supply of the analog terminals and the maximum ampacity of the terminals Furthermore the bus controller includes...

Page 16: ...automatically grounded if the bus controller is snapped on a grounded mounting rail The function of FE is to discharge interferences Note Functional earth ground 1 4 and 2 4 has to be connected addit...

Page 17: ...Table 3 2 2 1 1 Terminal assignment of supply connector 3 2 2 2 Power Dissipation Calculations for a Scalibur Controller The power dissipation of the bus controller equals the sum of the power require...

Page 18: ...datasheets in order to determine the current consumption of the connected actuators and sensors For an estimation it is often sufficient to check whether the supply can be provided completely by the S...

Page 19: ...environmental temperature of 40 C 104 F For higher temperatures the load PPERI and PUSB must be reduced according to Fig 3 2 2 3 Example 1 Horizontal mounting position For an environmental temperatur...

Page 20: ...otective diodes can be destroyed by permanent overload Polarity reversal Parallel diodes In case of wrong polarity a high current is flowing which is blowing the external fuses Segment supply and main...

Page 21: ...gable and includes two terminal points connected inside the plug for each bus line Thus the TP FT 10 bus can be wired in one line without additional terminals and the ICS can be removed without bus in...

Page 22: ...ows 8 1 Windows 10 For older Scalibur Operating Systems or when using Windows 7 the proper driver has to be selected manually as follows If you connect the Scalibur to your PC for the first time Windo...

Page 23: ...w located under Network adapter as RNDIS Ethernet Gadget This acts as additional network interface which provides a local network access to the Scalibur 3 2 6 USB The USB type A socket accepts USB end...

Page 24: ...ff no voltage at segment circuit UM green voltage at main circuit 24 V DC off no voltage at main circuit UL green UBK 24 V supply UL logic supply OK off UBK UL not OK Table 3 3 2 1 Inline supply LEDs...

Page 25: ...ht 3 3 4 IO Status LED IO The communication state of the IO terminals is signalized by a dual colored IO LED located at the supply connector State Description off The IO server is not running green Co...

Page 26: ...5 Hz Time slice of about 2 s after red blinking allows manual reset of Sedona application and kits to state of delivery Table 3 3 6 1 Service LED How to reset IP address access credentials and Sedona...

Page 27: ...thernet port LEDs 3 3 8 RS 485 Termination RS 485 networks are using bus topology and are terminated at both ends with a termination resistor Additionally the data lines are pulled once with bias resi...

Page 28: ...vice settings are vital to the device operation and should be protected carefully To prevent unwanted accesses from the network while offering a stable configuration access which is independent of the...

Page 29: ...em time 2 Update IPv4 Settings configure IP addresses 3 Update IPv6 Settings configure IPv6 addresses 4 Switch Configuration configure the Ethernet switch Ethernet port assignment to IP interface RSTP...

Page 30: ...ed using Sedona programming 4 4 1 3 File Access via FTP The Scalibur has an SFTP server to access the file system This can be used to load software updates from the PC to the Scalibur The SFTP server...

Page 31: ...ropean Summer Time CEST can be configured in several ways SCA System Shell see 4 1 1 Commissioning website via Settings Date Time see 4 1 2 Workbench via Platform connection with the Niagara daemon un...

Page 32: ...Software 32 sysmik de Manual SCA 340 SCA 340 L Table 4 2 1 Testing data points via commissioning webpage...

Page 33: ...k LocalPlatform EthSwitch SysmikScaSwitchCfgView When using ring monitoring or RSTP the status of the respective ports activated deactivated is changed automatically The port status information shows...

Page 34: ...ce has more than one Ethernet port assigned to it the IP interface is accessible on each of these ports Also Ethernet traffic is forwarded between these ports so that several devices can be linked in...

Page 35: ...complete recovery of the communication in the ring is defined by the aging time of the switches in the ring 4 3 3 Rapid Spanning Tree Protocol RSTP The Rapid Spanning Tree Protocol allows to build arb...

Page 36: ...k LocalPlatform EthSwitch Lan1State Lan4State Status Boolean true ok FORWARDING false ok BLOCKING xxx stale no current information available RSTP or loop not active xxx disabled status check disabled...

Page 37: ...the terminal The component ScaIo works as folder into which the hardware related components are added Furthermore it provides an Action Restart IO to restart the IO server Each terminal component has...

Page 38: ...dbus RTU Modbus Rtu Enabled Modbus Rtu Baud Modbus Rtu Parity Modbus Rtu Stop Bits Niagara enabled in case the parallel operation of Niagara and Sedona is not wanted Niagara can be deactivated or agai...

Page 39: ...og alarming scheduling web visualization report generators and interfaces to e mail SMS data bases and other All the engineering is done with a single tool Workbench 4 5 1 Local IO Access The componen...

Page 40: ...rted as proxy points to the station via Add Some data points have specific functions Measurement ranges of the analog input terminals can be configured with the additional property Ai Type of the prox...

Page 41: ...alibur by serial interfaces according to the M Bus standard for connection of up to 30 M Bus slaves and are controlled with the Niagara M Bus driver The interface names of the serial terminals are ass...

Page 42: ...Software 42 sysmik de Manual SCA 340 SCA 340 L Fig 4 5 2 1 SerialPortPlatformServiceNpsdk Fig 4 5 2 2 Interface configuration of IB IL RS UNI...

Page 43: ...red via Station Config Drivers SysmikScaIoNetwork localPlatform IoRemoteAddr Address setting Description invalid address empty string remote control deactivated default valid IP address IO server acce...

Page 44: ...Release values of priority control If several sources try to access the same IO channel the following ranking applies Rank Component 1 Commissioning website i e manual override in test mode 2 Sedona 3...

Page 45: ...range 0 10 V if applicable Table 4 6 3 Default values of priority control Some actions have command character These do not change the priority level but are processed in their order of occurrence or...

Page 46: ...IB IL DALI MM A DALI terminal can adress up to 81 data points 64 short addresses 16 group addresses one broadcast The ressource demand depends on the number of DALI ballasts and how they are controll...

Page 47: ...ata blocks to the Flash However these are almost negligible in comparison to the amount of data which is written in regular intervals like logging of history data or StationSave The write load caused...

Page 48: ...r Please verify that the cable is not damaged and is properly plugged into both sockets Check if the Device Manager shows the device Remote NDIS Compatible Device is shown as Network adapter If not re...

Page 49: ...mentioned range Check the Operating System version with the SCA System Shell or the Commisioning Website If the version is 1 0 1 2 then the device software needs to be upgraded Versions from 1 0 1 3...

Page 50: ...aseT MDI MDI X crossover automatic Aging time default 330 s Isolation LAN1 2 3 4 vs module test voltage 1500 V AC 1 min 1 LAN vs LAN test voltage 1500 V AC 1 min 1 RS 485 COM1 COM2 Max number of bus d...

Page 51: ...olute limits 19 2 V to 30 V DC Current drain at nominal voltage without local bus terminals IBK 170 mA Current drain at nominal voltage with local bus terminals without UM and US IBK 2 1 5 A 7 5 V log...

Page 52: ...85 symmetrical asymmetrical LON symmetrical asymmetrical 0 5 kV criterion B criterion A criterion A criterion A IEC 61000 4 6 conducted immunity 10 V m criterion A Emission according EN 61000 6 3 resi...

Page 53: ...ints 1226 100550 13 2 SCA 340 200 Niagara license for 200 devices 10000 data points 1226 100550 14 9 SCA 340 L LON TP FT 10 no Niagara license 1226 100550 06 4 SCA 340 L 005 LON TP FT 10 Niagara licen...

Page 54: ...B IL 24 DO 8 HD 8 transistor outputs 24 V DC 0 5 A 1 DU 2700172 IB IL 24 DO 16 ME 16 transistor outputs 24 V DC 0 5 A 2897253 IB IL 24 DO 32 HD 32 transistor outputs 24 V DC 0 5 A 2862822 IB IL 24 DO...

Page 55: ...IL DI 8 S0 8 S0 counter inputs digital inputs 2897020 IB IL MBUS M Bus master for up to 30 meters 2701927 IB IL RS UNI serial interface RS 232 RS 422 RS 485 2700893 IB IL RS 232 ECO 2 RS 232 up to 384...

Page 56: ...ogramming language SFTP Secure File Transfer Protocol to transfer files over IP network SSH Secure Shell for command line based access to devices in IP networks Switch Device to connect several networ...

Page 57: ...are A document with a list of embedded software components according to the documentation obligations of the respective license conditions is on the web server of the device The document can be access...

Page 58: ...Inline product range IL SYS INST UM E Phoenix Contact 2 LONWORKS FTT 10A Free Topology Transceiver User s Guide Echelon Corporation 3 LONWORKS Wiring Guidelines SysMik GmbH Dresden 4 First Steps with...

Reviews: