TFT/HxxxxPU71x16-xxx: user documentation
DOC/Protouch-71; V1.0
© Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com
24
/
27
5.2.
EMI / EMC Specification
–
EN 61000-6-2
Electromagnetic compatibility (EMC),
Part 6-2: Generic standards- Immunity for industrial
environments
–
EN 61000-6-4
Electromagnetic compatibility (EMC),
Part 6-4: Generic standards – Emission standard for
industrial environments
–
EN 55011
Industrial, scientific and medical (ISM) radio-frequency equipment –
Electromagnetic disturbance characteristics –
Limits and methods of measurement.
–
EN 55022
Information technology equipment -
Radio disturbance characteristics -
Limits and methods of measurement
EN 55024
Information technology equipment -
Immunity characteristics -
Limits and methods of measurement
1.1.1.
Emission
Emission requirements according to 2004/108/EC harmonized standard EN61000-6-2
Test
Standard
Limit
Radiated field
EN 61000-6-2
EN 55011:2009+A1:2010
CISPR 11:2009+A1:
30 – 230MHz: 40dBuV/m (QP)
230 – 1000MHz: 47dBuV/m (QP)
Radiated field
EN 61000-6-2
EN55022:2010
CISPR 22:2008
30 – 230MHz: 40dBuV/m (QP)
230 – 1000MHz: 47dBuV/m (QP)
1000 – 3000MHz: 56dBuV/m (AVG)
3000 – 6000MHz: 60dBuV/m (AVG)
Conducted emission
EN55011:2010
EN55022:2010
CISPR 22:2008
Mains AC
0.15 – 0.5MHz: 79dBuV (QP)
0.5 – 30MHz: 73dBuV (QP)
Telecommunication ports
0.15 – 0.5MHz: 97 to 87dBuV (QP)
0.5 – 30MHz: 87dBuV (QP)
Tab. 13 Emission requirements