32
6.4.
Mechanical Data
The enclosure can house a complete industrial control system with many basic functions. The
enclosure with its internal electronic system meets EMI/RFI electromagnetic standards
according to the European ”CE”- requirements (see paragraph 1.5). The figure below shows
the IPC/COMPCACT6-XS from its three sides.
Fig. 11 Three side view of the IPC/COMPACT6-XS enclosure
127mm
0
DSUB9 Connectors
109mm
4
8
.1
m
m
A1
A6
A2
A4
A3
A5
A8
A9
A11
A10
A7
1
2
7
m
m
Label
X [mm]
Y [mm]
D [mm]
A1
18.9
35.22
DSUB9
A2
51.9
35.22
DSUB9
A3
29.37
13.85
DSUB9
A4
96.0
31.42
8.5 x 14.5
A5
84.93
14.35
14.5 x 17
A6
77.4
36.05
14.5 x 15.5
A7
53.48
14.1
12
A8
68.87
11.6
4
A9
73.33
15.98
2.3
A10
73.33
12.68
2.3
A11
73.33
9.38
2.3