background image

IPC/CO MPACT6-XS: user documentation 

DOC/COMPACT6-XSE; V1.3 

© Syslogic  Datentechnik AG, CH-5405 Baden-Daettwil, Switzerland, http://www.syslogic.ch 

9

/

32 

 

The products are operated with electrical power. Before manipulating the products, they must 

be disconnected from the power source and from the communication signals. 

 

The products require set-up procedures before they  can be  operated. Before  being used in an 

actual  installation,  they  must  be  correctly  configured.  If  the  products  are  not  or  wrongly 

configured, they may malfunction in the intended application. 

 

The  products  must  be  assembled  and  installed  by  specially  trained  people.  The  strict 

observation of the assembly and installation guidelines is mandatory. 

1.6.

 

Electro-Static Discharge 

Electronic  boards  are  sensitive  to  Electro-Static  Discharge  (ESD).  Please  ensure  that  the 

product  is  handled  with  care  and  only  in  a  ESD  protected  environment.  Otherwise  a  proper 

operation is not garanteed. 

 

1.7.

 

Life Cycle Information 

1.7.1.

 

Transportation and Storage 

During transportation and storage the products must be in their original packing. The original 

packing  contains an  antistatic  bag  and  shock-absorbing  material.  It  is recommended, to  keep 

the  original  packing  in  case  of  return  of  the  product  to  the  factory  for  repair.  Note  that  the 

packing is recyclable. 

1.7.2.

 

Assembly and Installation 

Observe  the  EMI-precautions  against  static  discharge.  Carefully  read  the  assembly  and 

installation  guidelines  in  this  document  before  unpacking  the  products.  Make  sure  that  you 

have all the necessary items ready (including all the small parts). 

The installation procedures must be strictly observed. Note that deviations from the installation 

guidelines  may  result  in  degraded  operational  reliability  or  in  unfavorable  EM-radiation  or 

EM-susceptibility. 

1.7.3.

 

Operation 

The operating environment must guarantee the environmental parameters (temperature, power 

supply, etc.) specified in the technical specification section of the manuals. 

The  main  functionality  of  the  IPC/COMPACT6-XS  is  defined  by  the  application  programs 

running on the system. The application programs are not part of the delivery  by  Syslogic  but 

are  defined,  developed  and  tested  by  the  customer  or  a  system-integrator  for  each  specific 

application. Refer to the respective documentation for more information. 

1.7.4.

 

Maintenance and Repair 

The  IPC/COMPACT6-XS  features  error-  and  malfunction-detection  circuitry.  Diagnostic 

information gathered is transferred to the applications software where it can be used. In the rare 

case of a module hardware-failure or malfunction, the complete module should be exchanged. 

Summary of Contents for IPC/COMPACT6-1E

Page 1: ...CT6 XS DOC COMPACT6 XSE Revision Date Author Modification 1 0 30 07 2007 R Newbould Preliminary 1 1 25 01 2008 R Newbould Initial release 1 2 01 04 2008 R Newbould Additional information reg powering...

Page 2: ...atic Discharge 9 1 7 Life Cycle Information 9 1 7 1 Transportation and Storage 9 1 7 2 Assembly and Installation 9 1 7 3 Operation 9 1 7 4 Maintenance and Repair 9 1 7 5 Warranty 10 1 7 6 RoHS 10 1 7...

Page 3: ...Standards 28 6 2 2 Electromagnetic Emission 28 6 2 3 Immunity 29 6 3 Environmental Specification 29 6 4 Mechanical Data 30 7 Hardware 31 7 1 Firmware 31 8 Manufacturer Information 32 8 1 Contact 32 L...

Page 4: ...gram 13 Fig 4 IPC COMPACT6 XS 17 Fig 5 Service of battery or Compact Flash card 18 Fig 6 One possible way of mounting the IPC COMPACT6 XS onto the DIN Rail 19 Fig 7 Front view with connector markings...

Page 5: ...mpactFlash trademark of SanDisk Corporation PC 104 trademark of PC 104 Consortium Geode trademark of Advanced Micro Devices AMD Windows CE trademark of Microsoft Corporation Windows XP Embedded tradem...

Page 6: ...C NETIPC 6ALN 2 Slot chrome steel enclosure 3V Lithium Battery 1 4 Additional Products and Literature 1 4 1 Hardware The following items which have to be ordered seperately complemend the system Compa...

Page 7: ...Baden Daettwil Switzerland http www syslogic ch 7 32 1 4 3 Operating Systems Syslogic offers an implementation for the following operting systems OS Debian Linux Distribution IPC DEBIAN 40A Microsoft...

Page 8: ...rement control and communications applications in industrial environments The use of the products in systems in which the life or health of persons is directly dependent e g life support systems patie...

Page 9: ...ing in case of return of the product to the factory for repair Note that the packing is recyclable 1 7 2 Assembly and Installation Observe the EMI precautions against static discharge Carefully read t...

Page 10: ...or replacement The warranty expires immediately if the products are damaged of operation outside of the specified recommended operating conditions The warranty also expires if the date code or job num...

Page 11: ...or NVRAM 44pol IDE connector 2xUSB 2 0 interface PS 2 interface 10 100 Base T LAN controller Intel 82551 PC 104 bus 10 30V DC unisolated power supply 1 44MB ROM drive 2x RS232 interfaces 16550 compat...

Page 12: ...ace PS 2 interface 10 100 Base T LAN controller Intel 82551 PC 104 bus 10 30V DC unisolated power supply 1 44MB ROM drive 1x RS232 interfaces 16550 compatible CAN 2 0B Controller SJA1000 isolated inte...

Page 13: ...2 0 interface PS 2 interface 10 100 Base T LAN controller Intel 82551 PC 104 bus 10 30V DC unsiolated power supply 1 44MB ROM drive 1x RS232 interfaces 16550 compatible 1x RS422 RS485 halb full duplex...

Page 14: ...DDR400 SDRAM onboard memory soldered graphic controller 1920x1440x32bpp 85Hz 1600x1200x32bpp 100Hz watchdog RTC Temperature supervisor CompactFlash Type II socket DIL 32 Socket for SRAM or NVRAM 44pol...

Page 15: ...hapter 1 4 4 3 2 2 CAN Interface Configuration The CAN interface has to be configure according to the customers application Please refer to the IPC COMPAGP 1F documentation 1 chapter 1 4 4 for a detai...

Page 16: ...nfigure the CPU peripherals please consult the documentation of the CPU board 2 chapter 1 4 4 3 3 2 Serial Interface Configuration No hardware configuration has to be done 3 4 IPC COMPACT6L 1G 3 4 1 C...

Page 17: ...th many basic functions The enclosure with its internal electronic system meets EMI RFI electromagnetic standards according to the European CE requirements see paragraph 1 5 Fig 4 IPC COMPACT6 XS Impo...

Page 18: ...parts you must remove the cover by executing steps 1 and 2 of the following instructions Important Notes The battery socket is coded no wrong insertion of the backup battery is possible Handle the fl...

Page 19: ...the Enclosure There are two possible ways to mount the system onto a DIN Rail DIN Rail clamps can be mounted according to Fig 6 There are two versions of DIN Rails available flat C Rails h 7 5mm and n...

Page 20: ...I CE cerification correct mounting installation and cabling of the IPC COMPACT6 XS system according to these guidelines is absolutely necessary 5 2 Powering the IPC COMPACT6 XS System The logic voltag...

Page 21: ...If the input voltage drops below 10V the system doesn t work properly correct operation cannot be guaranteed The best efficiency of the power supply can be achieved if the external input voltage is a...

Page 22: ...tor Marking Interface Type X1 COM1 RS232 X2 COM2 RS422 RS485 Tab 8 IPC COMPACT6L 1G Interfaces 5 4 Grounding In some cases it is recommended to connect the shields of the cables to chassis potential a...

Page 23: ...ly recommended Fig 9 shows an non isolated system with common chassis ground Some of the communication ports are galvanically isolated ports for more information please refer to the documentation of t...

Page 24: ...tral Grounding Point I O Communication Link Abschirmung Shield Unisolated Node IPC System Nr 1 IPC System Nr 2 Potential Ausgleichsleitung min 10 mm 2 Kupfer Copper wire for Potential Adjustment min 1...

Page 25: ...25 C 1000 Vrms Isolation CAN to logic AC 60s 500m a s l Ta 25 C 1500 Vrms creepage distance CAN to logic 1 6 mm creepage distance CAN to chassis 2 5 mm IPC COMPACT6 1G and IPC COMPACT6L 1G specific r...

Page 26: ...ics over recommended operating range unless otherwise noted Parameter Symbol min Typ max Unit IPC COMPACT6 1E specific electrical characteristics full load power dissipation 24Vdc no external loads Pm...

Page 27: ...aud rate RS232 115 2 kBaud COM2 baud rate RS422 RS485 115 2 kBaud Non specific switching characteristics processor clock NETIPC 6A 6AN pclk 500 MHz memory clock IPC NETIPC 6A 6AN mclk 200 MHz Watchdog...

Page 28: ...ments EN61000 2 4 Generic standard emmission standard for industrial environments EN 50121 3 2 Railway applications Electromagnetic compatibility Part 3 2 Rolling stock apparatus EN 55011 Industrial s...

Page 29: ...80 AM 1kHz EUT with connection cable EN 50121 3 2 10V m 5V m A A PASS PASS Fast transients EFT Common Mode 5 50ns repetion freq 5kHz Controll and signal lines Power supply EN 61000 4 4 2kV 2kV B B PAS...

Page 30: ...netic standards according to the European CE requirements see paragraph 1 5 The figure below shows the IPC COMPCACT6 XS from its three sides Fig 11 Three side view of the IPC COMPACT6 XS enclosure 127...

Page 31: ...lies on definitive state hardware Therefore this information may be incompatible with the prototyping board hardware Important Note This document always covers the newest product revision listed in Ta...

Page 32: ...ucts and their use If you want to contact the manufacturer directly please send a fax or email message containing a short description of your application and your request to the following address or u...