background image

Figure 4.1.6. Hardware recording interface.

4.1.4

Timed recording

In the section timed recording you can set-up a timetable to record files automatically (in addition or
independent of the trigger). You set-up a  

Starting time

, e.g. every Monday at 10 am (select

Weekly > Monday > once a week > 10 > 00

) or now (select 

Hourly > Every hour >

 minutes: 1

minute from now. The expert mode provides you with the features of CRON (as it is known on
LINUX systems) to set-up the start time.
At the 

Starting time

, the MR starts recording according to the settings in the 

Parameters 

section.

Every 

Period between recordings

 starts with a recording of 

Recording duration

. The rest of the

period, the MR is idle.  

Number of recordings

  tells the MR how often this procedure will be

repeated.
NOTE: Timed recording continues until you disable it or the unite is switched off.

 

Figure 4.1.7. Timed recording interface.

MR3000CMR3000C_TR_v2.0_rev1.odt 

 subject to technical change without notice

30

Summary of Contents for MR3000C

Page 1: ...Manual MR3000C MR3000TR Firmware Version 2 0 x SYSCOM Instruments SA Rue de l Industrie 21 1450 Sainte Croix Switzerland Tel 41 24 455 44 11 Fax 41 24 454 45 60 sales bartec syscom com www bartec syscom com ...

Page 2: ...ry 15 2 5 4 Relay board 16 2 5 5 Sensors 17 2 6 Battery pack optional 17 3 SET UP of the MR3000 19 3 1 Connecting to the MR3000 for the first time direct connection 19 3 1 1 Wireless connection 19 3 1 2 Wired connection via Router 22 3 1 3 Wired connection without router 23 3 2 Connecting to the MR3000 in the field remote connection 23 4 The Web User Interface WebUI 25 4 1 Start 25 4 1 1 Manual re...

Page 3: ...message 66 4 4 6 Test Pulse 66 4 4 7 Relays 67 4 4 8 Advanced settings 67 4 5 VIEW 68 4 5 1 Acquisition 68 4 5 2 Background 69 4 6 Master functionality 70 4 6 1 Config Status 71 4 6 2 Common Trigger 72 4 6 3 Common Alarm 1 and 2 73 4 7 Recording List 74 4 8 System warnings 75 4 9 Rest API 78 5 OPERATING WITH THE MR3000C TR 79 5 1 Preparing the MR for field use 79 5 1 1 Construction site monitoring...

Page 4: ...ional services 88 5 3 1 Embedded SFTP server 89 5 3 1 1 FireFTP 89 5 3 1 2 Filezilla 91 5 3 1 3 WinSCP 91 6 Firmware history 92 Appendix A Internet access for the MR 93 Appendix B SAFETY INSTRUCTIONS 95 MR3000C_TR_v2 0_rev1 odt subject to technical change without notice 4 ...

Page 5: ...MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 5 ...

Page 6: ...o possible to remotely change the most important parameters of the instruments In this way it is possible to manage many vibration surveys directly from the personal office The memory storage capacity of the MR3000 has been increased using off the shelf SD Flashcard The data storage is managed by a file system The MR3000 systems are pre configured for the use with internal or external sensor The c...

Page 7: ... High reliability Low maintenance Compatibility with SCS cloud software 1 2 Specifications Wireless technology Protocol IEEE802 11 b g n Mobile network Europe Dual Band UMTS HSPA 900 2100MHz Quad Band GSM GPRS EDGE 850 900 1800 1900MHz America Dual Band UMTS HSPA 850 1900MHz Quad Band GSM GPRS EDGE 850 900 1800 1900MHz Operating Temperature 20 C up to 70 C Operating Humidity up to 100 RH 1 3 Appli...

Page 8: ...mpliance The MR3000C TR can be used to measure vibrations according to the following norms Construction sites DIN 4150 2 and DIN 4150 3 Germany SN 640312a Switzerland Circulaire du 23 07 1986 France BS 5228 UK UNE 22 381 Spain NP 2074 Portugal Blasting RI 8507 OSM Regulation USA AS 2187 2 Australia Arrêté du 1994 France BS 7385 2 UK MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change witho...

Page 9: ... Wi Fi antenna 4 Knurled screw 5 Knurled screw below MR 6 Mounting plate 7 Lid 8 GSM antenna 3 GSM antenna 4 Knurled screw 5 Knurled screw below MR Figure 2 1 1 Mechanical drawing of the MR3000C Top view and side view MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 9 ...

Page 10: ... connector to hook up an external GPS antenna Figure 2 2 1b The LAN port is also referred as the Ethernet port The MR3000TR has one supplementary connector AUX dedicated to the connection to the relays Figure 2 2 1b a b c Figure 2 2 1 Front view of a MR3000C showing the two sockets for power and LAN b MR3000 face with GPS connector c MR3000TR showing connectors for power LAN AUX and GPS with cap M...

Page 11: ...t an additional power source for redundancy 2 2 3 GPS optional Here you connect to an appropriate GPS module for time synchronization 2 2 4 AUX The AUX connector is available only for the MR3000TR and it is dedicated to the relay cable 81000580 In the MR3000TR there are 2 relay outputs for the connection to external devices 1 hardware trigger input to start the measure with an external trigger The...

Page 12: ... related to the MR3000C LINE 1 Typology of the instrument together with the battery voltage LINE 2 IP address of the instrument When the 3G module is up and there is no LAN connection then the display shows the characteristics of the mobile signal LINE 3 Values set for the trigger on the three axes When trigger is disabled or its mode is STA LTA this is clearly shown on the LCD display LINE 4 Numb...

Page 13: ...MR is active and blinking while the unit is starting up The yellow DATA LED is on if the MR is recording and event The red ERROR LED indicates if any error or warning occurs on the MR3000 If it blinks slowly then a warning has been detected if it is permanently ON red colour then an error has been detected 2 4 1 List of errors and warnings In the following a list of the warnings and errors is pres...

Page 14: ...ly equipped with a 3G modem device covering GPRS EDGE and UMTS standard This device is used to establish communication if the MR is out in the field To use the 3G module you have to insert a SIM card inside the MR Figure 2 5 1 Inserting a SIM card in the MR The procedure is quite simple Ensure the MR is turned off Unscrew and open the lid Pull out the SIM card tray by pushing the button at the lef...

Page 15: ...r of your PC allows you a fast access to all the data of the MR3000 If you have copied all the data you can format the SD Card 2 5 3 Internal backup battery The MR is equipped with a real time clock with back up lithium battery Even if the MR is switched off the clock continues working The lithium battery is located on the main board at the lower right end Replacement by the user is possible witho...

Page 16: ... relay outputs to connect external devices typically for alarming like sirens gyrophares with current 2 A and tension 30 VDC one hardware trigger input to trigger the instrument with an external device see Table 2 2 1 An alarm box is available in case a higher power is needed Please visit http www syscom ch products mr3000tr our contact support bartec syscom com to have further information on it M...

Page 17: ...erometer Concerning the orientation the MR3000 and the external sensors can be ordered for horizontal mounting typically on the ground or for vertical mounting on the walls Figure 2 5 5 The internal triaxial velocity sensor is located at the rear end of the housing 2 6 Battery pack optional An external battery can be used together with the MR3000C TR It is a lead acid gel cell 5 Ah with integrated...

Page 18: ...Figure 2 6 1 The external battery pack with integrated charger MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 18 ...

Page 19: ...outer This method offers the most possibilities and needs no configuration at start up but you need a router If the router has access to the Internet you can do everything with your MR3000 including firmware upgrades If you have a router with PoE Power over Ethernet feature the MR3000 is powered through the LAN cable You can attach many MRs to the router and talk to all of them simultaneously The ...

Page 20: ... a network If you are already connected to another network you will have to disconnect from this network first Select the MR3000 network and click connect and enter the passphrase and click connect Figure 3 1 1 Wi fi settings for Windows MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 20 ...

Page 21: ...tablished the Wi Fi connection you start the Web browser to talk to the MR3000 Enter the IP address of the MR always 192 168 30 1 for the Wi Fi connection in the Web Browser You will then be prompted for the user name user and the password serial number of your MR e g 13050130 After a successful authentication the main page of the Start screen is shown First you have to enter user name and passwor...

Page 22: ...e to one of the LAN ports of your router Your PC needs a connection to the same router wired or Wi Fi Make sure to disable any other LAN connections on your PC Figure 3 1 4 RJ45 connector on top LEMO connector below After connecting the MR to the router the LCD of your MR3000 says Sending DHCP requests After a few seconds the MR3000 shows the IP address on the LCD e g NET 192 168 1 27 This IP addr...

Page 23: ...he IP address of your computer The default IP address of the MR is 192 168 1 2 and is displayed on the LCD Therefore you must assign a static IP address to your computer on the same sub network as the MR For example 192 168 1 3 Zeroconfig address assignment using APIPA Automatic Private IP Address Assignment is not supported 3 2 Connecting to the MR3000 in the field remote connection For a remote ...

Page 24: ...he WebUI To establish communication with the MR3000 you have to enter the Domain Name DDNS or the virtual address OpenVPN in the Web browser For OpenVPN you have to install the OpenVPN client on your PC or smartphone with the appropriate certificates as well To communicate with the MR you have to start the VPN service on the PC For installation of the VPN client on your PC please refer to Appendix...

Page 25: ... to recording Relays can be configured in this tab as well View allows a real time graphical display of the waveform data or the vibration level background recording Master allows you to set up a network of MR3000C MR3000TR to perform common trigger and common alarm This feature is only available if the Master Slave option is activated on this recorder which is called the master Recording List sho...

Page 26: ...nload and further analysis on the PC Figure 4 1 1 Manual recording interface 4 1 2 Trigger recording The trigger is a feature that allows the MR to start recording if the signal reaches the threshold level In this case the MR3000 is triggered When the signal comes back below the threshold level the trigger is idle see section Activity on the Status screen Velocity sensor Let s discuss about the st...

Page 27: ...hreshold level that is set up in the section Level If the vibration exceeds the threshold level on a specific channel the trigger condition becomes true for this channel In the section Combination you choose which channels are needed to fulfill the general trigger condition and subsequently lead the instrument to start recording You may consider only 1 axis channel e g Z vertical or more If you co...

Page 28: ...nd pass trigger filter between 0 5 and 15 Hz is applied on the signal This means that en event is created only if both the conditions are fulfilled the trigger condition is exceeded the peak is associated to a frequency in the range 0 5 15 Hz In case of Level the acceleration threshold for the trigger activation can be chosen on each of the three axes NOTE Due to the presence of the trigger filter...

Page 29: ...ecording This section is dedicated only to MR3000TR In case of MR3000TR an additional section is present regarding the settings for the hardware trigger since the instrument can be triggered via hardware by using an external input The input must be a digital hardware trigger The user should short the signal Trigger and GND to start a trigger consider the datasheet of the MR3000TR and the applicati...

Page 30: ...ou with the features of CRON as it is known on LINUX systems to set up the start time At the Starting time the MR starts recording according to the settings in the Parameters section Every Period between recordings starts with a recording of Recording duration The rest of the period the MR is idle Number of recordings tells the MR how often this procedure will be repeated NOTE Timed recording cont...

Page 31: ...llows to simultaneously save the peaks of signal vector sum and dominant frequency Peak KBFTi Dominant Frequency allows to simultaneously save the peaks of signal KBFTi and dominant frequency where KBFTi represents the maximum of the moving average of the weighted vibration severity for each period by default 30 seconds according to DIN 45669 1 and DIN 4150 part 2 KBFTi according to DIN 45669 1 an...

Page 32: ...updated automatically ID contains o Name of the MR3000 by default this is MR3000 followed by a dash and its serial number You may change the name according to your needs see Section 4 4 1 o Comment a description of the location where you have installed the MR This text is shown together with the name in the messages see Section 4 4 1 o UID unit ID serial number can not be changed o firmware versio...

Page 33: ...d push is currently going on disabled service is not active o Timed recordings shows 3 different status active the MR is either recording see trigger status above or in the period between two scheduled recordings idle service is active but start time has not been reached yet disabled service is not active LAN displays the IP address of the MR on the Ethernet port and the MAC address of the interfa...

Page 34: ...time calculated on the remaining erase cycles this functionality is available only with the Swissbit SD cards It also shows the number of events on the MR Indicators shows the current temperature inside the MR the input voltage and the uptime time since the last boot of the system If any error is present in the system it is highlighted in red If a warning is present it will be highlighted in yello...

Page 35: ...ilable only with the SWISSBIT SD cards You can format the memory SD card with the relative button this erases ALL the data memorized on the card A dialog box pops up and ask for confirmation Wait until the formatting is done takes approx 10 seconds Figure 4 3 1 Subsection dedicated to SD card 4 3 2 Time In this tab you configure the timing services of the MR In the Status section the following inf...

Page 36: ... the internal clock and the accurate time to synchronize the clock once a valid NTP server is set up and Internet connectivity is available If the synchronization was successful the time of the synchronization is shown as Last clock update in the Status section The accuracy of the synchronization depends on the quality of the Internet connection and also of the servers you choose The closer you ar...

Page 37: ...a b Figure 4 3 2 Subsection dedicated to the time synchronization in case of mode Disabled and mode Network NTP MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 37 ...

Page 38: ...cted to Internet You can check that with the ping button see chapter 4 3 12 If the MR fails to receive a reply of the DHCP request the settings for the Static configuration are used if the case Fallback to static IP if DHCP fails is checked Static means that the MR will use the static IP address provided below You should select this option if you plug the MR directly to your computer You also need...

Page 39: ...the IP address of the MR 4 3 4 Wi Fi You can enable the Wi Fi service and the Wi Fi hardware by checking the Enabled checkbox When enabled the MR behaves as a Wi Fi access point This means it broadcasts a network name SSID and you can connect to it with your Laptop or Smartphone The MR uses a static IP address 192 168 30 1 and will give a dynamic IP address to your Laptop Smartphone when the conne...

Page 40: ...ually it could be switched on only when desired in order to reduce the consumption The mode can be either Always activated the module is always ON or Time Scheduling In the second case you can choose at which time it automatically switches on and off If some files have been recorded during the rest period of the 3G module they will be sent when it is switched on see also chapter 4 4 4 to based on ...

Page 41: ...n are present The module inside the MR3000C allows you to send data with 2G or 3G connection If you wish to enable the 2G 3G connection click on the Enabled box You also have to enter the Access point name which is provided with your SIM card documentation Certain GSM providers require a Username and a Password You can also choose to allow roaming and to choose if the mobile connection is the pref...

Page 42: ...Figure 4 3 5 Subsection dedicated to the mobile communication MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 42 ...

Page 43: ... in the network The DDNS service makes sure that you can access your MR through a persistent domain name e g mymr dyndns org Communication with the DDNS service needs an Internet connection check with the PING function as described in chapter 4 3 12 For further details please check the web site of the DDNS service provider of your choice the MR supports the following services dyndns no ip ovh dynd...

Page 44: ...ress and if the MR is connected via 3G connection or via wired connection The virtual address is shown here and on the Status screen in the VPN section The configuration is fairly easy you just have to click the Enabled box then upload the 4 configuration files on the MR and click on Apply The configuration files sometimes referred as VPN keys are provided by the provider of the VPN service Commun...

Page 45: ...ion A unique e mail account for all devices can be used since it is only used to send e mails To illustrate that let s show an example using GMAIL If you use a different e mail service you will have to check the documentation of your service provider to figure out the URL and the port of the SMTP server Create an address e g mr3k syscom gmail com on the Gmail Web site Enter this address as User ad...

Page 46: ...e ftp prefix You may add a specific subdirectory to the host name e g myftphost com mydir mr in this case the MR will create the corresponding subdirectory on the FTP server Sub directory for this specific MR This directory is created below the main directory as set up under Host By default the Name of the MR is used see chapter 4 4 1 alternatively you may use the UID Serial number of the MR see c...

Page 47: ...p mode are enabled you will have two copies of the same file on your FTP server of course this also doubles the amount of data sent to the FTP server NOTE The name of the main directory for a specific MR main dir events 2014 is what you have set up as Sub directory Name of the MR If you change this setting the MR will generate a new directory on the FTP server 4 3 10 SCS Cloud The MR3000 can be co...

Page 48: ...in the SCS cloud software These parameters are Name of the device Comment Trigger levels Alarm 1 parameters Alarm 2 parameters Background settings During the synchronization both the MR3000C TR firmware and the SCS check if the parameters have been changed There are three cases 1 The parameters have been changed only in the firmware the SCS is updated during the synchronization 2 The parameters ha...

Page 49: ...ebUI access and for the SFTP service see chapter 5 3 1 By default the password is the serial number of the MR shown as UID on the Status screen see chapter 4 2 NOTE please make sure that the new password will be remembered Figure 4 3 11 Subsection dedicated to the authentication 4 3 12 Upgrade In this section you find The Ping button allows you to send a ping request to a Web site It s useful if y...

Page 50: ...ed to upgrade the MR3000 at the end of a monitoring session Figure 4 3 12 Subsection dedicated to the Upgrade The Upgrade from files feature allows to flash a new firmware directly from your PC without Internet access on the MR The internet access is needed only on your PC In this case please open a browser on your PC and insert the URL given by Syscom but without the final part For example Entire...

Page 51: ...u may use the Wi Fi access to communicate with the MR The Reboot button initiates a warm start of the MR Figure 4 3 13 Subsection dedicated to the Maintenance and details on the import section The User Parameters section is useful to import user parameters defined in other devices or even in the same device and to export them for future use During the import phase you can choose between a standard...

Page 52: ...f measure and the serial number are indicated With modify settings you can modify the unit of measure of the sensor As you can see in Figure 4 3 14b it is possible to select metric or imperials units in particular mm s default value or in s NOTE if you do not want to change the settings please click on CANCEL because otherwise the MR will reboot a b Figure 4 3 14 Subsection dedicated to the sensor...

Page 53: ...voltage measured decreases below this level release threshold meaning that the warning condition is released when this level is exceeded Figure 4 3 15 Subsection dedicated to the system monitoring 4 4 User Parameters In this part you set up the general parameters of the system 4 4 1 General Here you can modify the Name ID of the MR by default mr3000 followed by a dash and the serial number UID of ...

Page 54: ...aw signal and the sampling rate Figure 4 4 2a Velocity sensor In case of velocity sensor the pre defined Filter types can be selected among the choices shown in 4 4 2b It is important to select the adequate filter for the desired application The filter Bandpass of the sensor means that there is only the anti aliasing filter applied on the signal which cuts off the frequency contents above 80 of Ny...

Page 55: ...s case the notification service of the MR3000 sends an e mail or SMS to the people listed in contacts where Alarm 1 or Alarm 2 have been checked see chapter 4 4 4 Indicator time seconds is the period between the first exceeding of the alarm threshold and the end of the alarm condition For event related alarms this setting is not relevant For the difference between Alarm based and event based messa...

Page 56: ...n all the other four cases not only the velocity peaks are taken into account but also the frequency values In other words the regulations define velocity limits that are depending on the frequency For this reason the maximum peak and the relative dominant frequency constitutes a unique point to be placed on the graph and to be compared with the limit curve In Fig 4 4 4 the limit values defined by...

Page 57: ...where the curves are divided according to denomination defined in the norm The button Restore allows to come back to the default configuration of the concerned norm If the German or the French regulation is selected the control of the limit values is done on each of the three axes The alarm is activated if at least one of the three axes exceeds the limit values Figure 4 4 5 Choice of the limit cur...

Page 58: ... that with the lowest value of the dominant frequency is considered Once chosen the desired reference curve it is possible to see the values in the underlying table Fig 4 4 5 Moreover the alarm can be set as a curve having the same trend of the reference norm selected but with reduced values The reduction in percentage can be chosen from 1 to 100 This option can be used for a lower alarm level for...

Page 59: ...ain page Alarm see Fig 4 4 7 Figure 4 4 7 Subsection dedicated to the alarm settings with information on the norm selected NOTE If an alarm is defined on an implemented or on a user defined norm it is not possible to set the trigger value higher than the alarm threshold The reason is the fact that the frequency must be calculated and therefore an event must be created Contrarily in case the alarm ...

Page 60: ...et for each channel Moreover each channel can be set completely independently meaning that X can have 4 points Y no points and Z 3 points The button Restore allows to reset the name and the values defined Figure 4 4 8 Settings for a user defined norm for a background recording If the user defined norm is activated in the section Start Background recording the mode Peak Dominant frequency must be a...

Page 61: ...re 4 4 10 a Setting of the background recording b Warning message caused by the definition of the alarm as in Fig 4 4 9 In Figure 4 4 11 the alarm settings in case of accelerometer are shown MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 61 ...

Page 62: ...ssages The MR3000 is able to automatically send emails and SMS with the desired options to the user defined contacts Contacts In this subsection it is possible to add Contacts for the notification service Contacts are people who receive notification from the MR3000C TR To add a new contact click on the Add button To edit a contact just click the corresponding line Clicking the Del button will dele...

Page 63: ...to Event recording or regardless of the recording of an event when the vibration reaches the Alarm threshold see Section 4 4 3 The difference between the two methods is Alarm messages related to Event recording include additional information such as the peak of the event peak of the vector sum of the event and the dominant frequency of the event To use this option you have to make sure that the tr...

Page 64: ...mation to any of the contacts as for example a Daily Message see Section 4 4 5 as you can see in the following section Messages If the Network option is active there are additional messages for common Alarm and common trigger see Section 4 6 After having changed something on the contact list don t forget to click on the Apply button In Fig 4 4 13 the main page related to contacts is displayed In e...

Page 65: ...ifferent messages are shown In case of Alarm 1 Alarm 2 and Daily message the user can also add a comment that will be displayed in the message a b Figure 4 4 14 Subsection dedicated the notifications for the selection of messages MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 65 ...

Page 66: ... mode The recipients of this message are set up in the section 4 4 4 The user can also decide to receive the daily message at boot Figure 4 4 15 Subsection dedicated to the daily message 4 4 6 Test Pulse NOTE This subsection is present only if an accelerometer internal or external or an external velocity meter is used together with the MR Figure 4 4 16 Subsection dedicated to the test pulse MR3000...

Page 67: ...or or a warning is detected Recording the relay is activated at the beginning of a recording of a manual recording a timed recording a trigger recording a common trigger recording or a hardware trigger recording The test pulse is not taken into account Common Alarm 1 common Alarm 2 and common trigger are available only for the master device in a network of different interconnected devices How long...

Page 68: ...iles are pushed to the server choosing a value included from 1 to 60 minutes Moreover you can choose to push the files after a trigger event Figure 4 4 18 Subsection dedicated to the advanced settings 4 5 VIEW 4 5 1 Acquisition This service provides a real time display of the waveform data as they are recorded if the trigger criteria see chapter 4 1 2 are fulfilled The data are filtered and the sa...

Page 69: ...olor but lighter shade the envelope of the signal with the true peaks is drawn The Vertical zooming or simply zoom is exactly what its name suggests A value of 1 means no zooming a value of 100 means that signal is multiplied by 100 Figure 4 5 1 Real time visualization of data 4 5 2 Background This service provides a real time display of the vibration level of the past background file This presume...

Page 70: ...ent in the same network it is called the Master The other instruments are standard instruments called Slaves Communication in the network is handled by the Master With this feature some MRs up to 32 can be integrated in a network to perform common trigger and common alarm In case of Master functionality a good synchronization among the MRs in the network is highly recommended This is achieved by s...

Page 71: ...l IP address as shown on the LCD of each MR If the MRs have a virtual address VPN address in addition to the physical address you have to use the virtual address Don t forget to check the Enabled box and click on Apply The column MRs status should show ok this means the Master is able to communicate with the Slave The column Time synced with master should show yes This means the time difference in...

Page 72: ...umn Selected the logical combination of this condition is shown The logical combination of all conditions is shown in the section Logic function A simple example You have to install 3 instruments to monitor the vibration in a 5 story building 1 MR is in the cellar one MR at the middle of the building height and one on the 5th floor As there is a lot of activity in the rooms from 2nd to the 5th flo...

Page 73: ...k To get only files due to a common trigger from the Recording list you will have to apply a filter for the Reason chapter 4 7 With the button Start and Stop you can also start a new recording among all the sensors present in the network without waiting for the activation of the common trigger 4 6 3 Common Alarm 1 and 2 Common Alarm means that there is a voting logic for the alarms Here you define...

Page 74: ... arrow keys at the upper right edge to go to the first last page the simple arrows go the the next previous page If you move the mouse over a single line additional detail information for this file is shown Clicking on the line will start an immediate download of the file If you have EAWlight the WINDOWS software to visualize the data installed the file peak or event is shown immediately You may u...

Page 75: ... without any interruption recordings peak files if the vibration level was below the trigger threshold or additionally event files if the vibration level exceeds the trigger threshold throughout the whole monitoring period it is NOT possible to erase single files The SD card is considered as documentary evidence Figure 4 7 2 Subsection dedicated to the filters for the recording list 4 8 System war...

Page 76: ...rm 1 has been selected even if it has not been considered in the User Parameters section Figure 4 8 2 Automatic warning produced by the software related to the wrong settings shown in Figure 4 8 1 MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 76 ...

Page 77: ...inant frequency are calculated but not the vector sum If the setting Mode is change to Peak Vector Sum then the warning disappears see Figure 4 8 5 Figure 4 8 3 Setting of the alarm where the Alarm 2 is based on the Vector Sum Figure 4 8 4 Settings of background recording with selection of the peak and the dominant frequency that causes a conflict with the alarm settings MR3000CMR3000C_TR_v2 0_rev...

Page 78: ...tor sum that does not cause a conflict with the alarm settings 4 9 Rest API The REST API functionality for firmware 1 6 and above Please contact Bartec Syscom for more information at support bartec syscom com MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 78 ...

Page 79: ...e data coming from the MR3000 For more information please visit the web address http scs bartec syscom com visit the dedicated website page http www syscom ch products software scs cloud software contact Bartec Syscom at info bartec syscom com In the following we will present the operational procedure for a typical application with the MR3000C TR 5 1 1 Construction site monitoring Let us suppose t...

Page 80: ...e settings STEP 2 Settings of the 3G module NOTE This step is necessary in case a SIM card is used Turn off the MR3000 insert the SIM card and then turn it on If requested insert the PIN code of the SIM card Choose the activation interval of the 3G module We suggest to activate it MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 80 ...

Page 81: ...ettings of the 3G module In a short time interval at the end of the day if an immediate communication of the recorded values is not needed MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 81 ...

Page 82: ...ate which does not exceed 10 times the maximum frequencies expected in the measurement For further details please refer to chapter 4 4 2 Figure 5 1 3 Settings of acquisition parameters STEP 4 Trigger recording Choose the pre and post event duration Choose the max length Choose the trigger combination We suggest to trigger when the threshold on one of the three axes is exceeded X or Y or Z We sugge...

Page 83: ...5 Alarm levels Configure alarm 1 based on the desired recording mode and on the reference norm Configure alarm 2 based on the same principles Figure 5 1 5 Settings of the alarm MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 83 ...

Page 84: ...u want to send an SMS to the site supervisor if the vibration level exceeds the alarm thresholds Moreover we add a new contact called Operator that will be informed about every specific notification on the system More details can be found in chapter 4 4 4 In particular in case a message should be sent to site supervisor if vibration level is exceeding the alarm threshold then a dedicated contact c...

Page 85: ...CS and the creation of a new account please visit the SCS website or the dedicated webpage on the Bartec Syscom website Figure 5 1 7 Settings of the connection MR3000 SCS STEP 8 Installation at site You should choose a convenient place where an AC power plug is available in case of a long monitoring and with a reasonably good GSM UMTS coverage The sensor must be installed in a perfect horizontal o...

Page 86: ... External 12 VDC Battery Any 12 V battery may be used as long as it meets the capacity requirements of the application The battery may be charged by a solar panel with a battery charger The input voltage range of the MR3000C TR is from 9 V to 13 5 V DC 5 2 2 Battery Pack The battery pack see Fig 5 2 1 contains a lead acid gel battery and a battery charger The battery capacity is 5 Ah Depending on ...

Page 87: ...y Alternatively the MR3000C TR may be powered by a 12 VDC AC DC supply In case of power interruption the MR3000C TR will shut down without any notification Figure 5 2 2 MR3000C connected to an external AC DC supply MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 87 ...

Page 88: ... the PoE switch to accommodate for power interruptions Note A PoE surge protection may be added close to the MR3000 for internal PoE protection Figure 5 2 3 MR3000C and a laptop being powered from a PoE switch via LAN connectors 5 2 5 Combined Power Options The MR3000 may also be powered by a combination of PoE and an auxiliary external 12 VDC supply battery or AC DC In this case the MR3000 automa...

Page 89: ...osed to be there just click the refresh button Below you will find a list of SFTP clients with a quick explanation on how to use it All these software are free and widely available on the Internet 5 3 1 1 FireFTP If you are using Firefox as Web browser this is the favored SFTP client You have to install the add on FireFTP This SFTP client is directly integrated into your Web browser To install it ...

Page 90: ...he MR you navigate on the left hand panel PC to the directory of this MR on the right hand panel you navigate to the directory user Then you open the menu Tools and select Sync Directories Sub Directories As shown in the picture below the tool has already pre selected the desired action i e to Download both directories background and events to the local side By clicking the Sync button the transfe...

Page 91: ...w Site In the host field enter the IP address of the MR3K For the protocol choose SFTP For the logon type choose normal Then enter your login and password and click Connect 5 3 1 3 WinSCP As an alternative to Filezilla there is WinSCP You can get it at this address http winscp net eng download php The first time you launch it click on the New button MR3000CMR3000C_TR_v2 0_rev1 odt subject to techn...

Page 92: ...6 Firmware history The list of the changes in the firmware can be seen at the following URL MR3000_firmware_release_note pdf MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 92 ...

Page 93: ... Area Network From this bubble the MR can reach the outside world Internet and e g push data to the FTP server but you can t reach the MR from the outside world We don t want to enter into thorough explanations about the WHY you can t reach it It s a question of IP addresses deep understanding of what is a LAN and other technical details that are not subject of this manual To reach the MR from the...

Page 94: ...form the outside world is possible without any additional settings The use of DDNS is not possible 3 You use the 3G service with a special SIM card providing a public IP address The MR acquires a public accessible from the outside world and dynamic changing often IP address Result FTP push service SCS and the NTP service work nicely and you can remotely change parameters with the SCS If the SCS is...

Page 95: ...mpliance with the essential requirements and other relevant provisions of Directive 2014 53 EU Installation Set up Install and use the product in accordance with the instructions below in order to avoid any risk of fire electrical shock or damage and or injuries Installation The product should be installed near an easily accessible power supply Install the product on a stable level surface to avoi...

Page 96: ...onment Do not place the product in a room with oily smoke or steam Fire electric shock or warping may result Do not heat the case of a product with an internal lead battery above 50 C Such condition may damage the internal lead battery casing Situation Do not use the product when your hands are wet with the cover removed or with attachments not recommended by the manufacturer Disconnect the produc...

Page 97: ...symbol might be used in combination with a chemical symbol The chemical symbols for mercury Hg of lead Pb are added if the battery contains more than 0 0005 mercury of 0 004 lead By ensuring these batteries are disposed of correctly you will prevent potentially negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of the battery ...

Page 98: ...MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 98 ...

Page 99: ...MR3000CMR3000C_TR_v2 0_rev1 odt subject to technical change without notice 99 ...

Reviews: