eSATA External Storage
V1.0
13
Data
RAID REBUILDING
When one of the installed hard disk drive fails, replace the hard disk drive with new one and proceed RAID
rebuilding.
NOTE:
RAID rebuilding is not supported for the RAID0 level.
1.
When one of the installed hard disk drives fails, the beep sounds and RAID error LED blinks. Open
the right cover of the front panel by using the enclos
ed door-lock key and press the Mute button to release
the beep.
2.
System changes to the Degraded mode and the failed hard disk drive is displayed on the front LCD.
Degraded R5+4d
D:FOOO
y
The system is set to the RAID5 level and the first hard disk drives among
four failed.
3.
Replace the failed hard disk drive with a new one and proceed RAID rebuilding by pressing the Setup
button on the left.
RAID rebuilding?
<- Okay?
y
Select
Okay
by pressing the Setup button on the left.
4.
The system proceeds RAID rebuilding and the rebu
ilding status is displayed on the front LCD.
Rebuild d:ROOO
1h 31m
y
The system proceeds RAID rebuilding on the first hard disk drive among
four and it takes 1 hour and 31 minutes to complete it.
5.
When the RAID rebuilding is complete, it is displayed on the front LCD.
Active R5+4d
D:OOOO
y
The system completed RAID rebuilding on the first hard disk drive among
four.