机床产品
/Machine Tool Products
–
610-E5/610-H5 5-Axis Wood Operation Manual
How to Operate 21 Series Controller
–
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
m.
n.
o.
p.
q.
r.
s.
Move the detector or tool to the left of workpiece (point Px1 in Fig. A)
Press "Set Px1", the system will fill the current X axis machine coordinate into the Px1 column on the
screen.
Move the detector or tool to the right of workpiece (point Px2 in Fig. A)
Press "Set Px2", the system will fill the current X axis machine coordinate into the Px2 column on the
screen.
Now can see "Pxm" is shown on the screen. It's the middle function result calculated by the
controller.
Move the detector or tool to the left of workpiece (point Py1 in Fig. A)
Press "Set Py1", the system will fill the current Y axis machine coordinate into the Py1 column on the
screen.
Move the detector or tool to the left of workpiece (point Py2 in Fig. A)
Press "Set Py2", the system will fill the current Y axis machine coordinate into the Py2 column on the
screen.
Now can see "Pym" is shown on the screen. It's the middle function result calculated by the
controller.
For "Auxiliary Coordinate" in the bottom right corner, the X, Y coordinate will now be the value of
"Pxm" and "Pym".
Move the cursor to "Workpiece Coordinate P" and input the assigned workpiece coordinate number,
press F5 "Auto Set Aux. Coord," (Valid version
:
10.116.34)
System confirmation window will show up [Apply Aux. Coord. to the assigned workpiece
coordinate?], press [Yes] and the system will set the X, Y axis auxiliary coordinate value into the
assigned workpiece coordinate.
It's able to return to the "Set Workpiece Coordinate" screen with left arrow key.
Move cursor to the X coordinate of the workpiece coordinate requires setting and press "Apply Aux.
Coord,".
System confirmation window will show up [Apply Aux. Coord,?], press [Yes] and the system will set
the X coordinate of "Aux. Coord." to the workpiece coordinate which the cursor is at.
Move cursor to the Y coordinate of the workpiece coordinate requires setting and press "Apply Aux.
Coord.".
System Confirmation window will show up [Apply Aux. Coord.?], press [Yes] and the system will set