INPUT/OUTPUT SIGNALS
PAGE
|
59
Table 4-4 User I/O pin descriptions (Continued).
Important Note:
Use the interlock function to provide maximum operator safety. When the
Remote Interlock input is opened (voltage source removed), the internal shutter automatically
closes to block the beam path, the RDY LED turns Off, the SHT LED turns Off (regardless of the state of
the Shutter Open Request input), and all DC power is removed from the RF boards.