maintenance/
troubleshooting
69
SYNRAD OEM v30 Operator’s Manual Version 2
Troubleshooting
Table 5-4
Laser Enable input not connected
LED Indicator
LED Status
Output Signal
DB-9 Output Status
LASE (if tickle applied)
Off
Lase Indicator
Low
LASE (if PWM applied)
Off
Lase Indicator
Low
RDY Off
Laser Ready
Low
Overtemp Fault
Low
PWR Green
DC Voltage Fault Low
Table 5-5
Over Temperature fault
LED Indicator
LED Status
Output Signal
DB-9 Output Status
LASE (if tickle applied)
Off
Lase Indicator
Low
LASE (if PWM applied)
Off
Lase Indicator
Low
RDY Flashing
1
Laser Ready
Low
Overtemp Fault
1
High
PWR Green
DC Voltage Fault Low
1 See the Laser fault indications section for details.
Table 5-6
DC Voltage fault
LED Indicator
LED Status
Output Signal
DB-9 Output Status
LASE (if tickle applied)
Off
Lase Indicator
Low
LASE (if PWM applied)
Off
Lase Indicator
Low
RDY Off
Laser Ready
Low
Overtemp Fault
Low
PWR Blinking
1
DC Voltage Fault
1
High
1 See the Laser fault indications section for details.