8
Chapter1:GettingStarted
Default/ManualSwitchBehavior
Mode
Cross-volume Models
Independent-volume Models
Default
Autopoweron/off
Autopoweron/off
Manual
Autopoweron/off
Noautopoweron/off
Note:
Cross-volumemodelsrefertothosemodelsdesignedtobepaired
withexpansionunits,suchasRS814+.Independent-volumemodelsrefer
tothosemodelswhich,whenpaired,donotsupportexpandingexisting
volumesacrossthemainunitandexpansionunits,suchasRS214.
Expansionunitspairedwithindependent-volumemodelscanonlyform
independentvolumes.
RESETButtonBehavior
Volume Type Default/Manual
Switch Mode
Applicable
Models
Behavior
Cross-volume Default/Manual
RS814,
RS814+,
PresstheRESETbuttontoshut
downandrestarttheexpansionunit.
Independent-
volume
Default
RS214
PressingtheRESETbuttonwillshut
downtheexpansionunit,andthe
volumeinsidetheexpansionunit
willbeshownas"crashed."Restart
RS214toautomaticallyrestartthe
expansionunitandrestorethe
storagevolume.
Manual
PressingtheRESETbuttonwillshut
downtheexpansionunit,andthe
volumeinsidetheexpansionunitwill
beshownas"crashed."Manually
restarttheexpansionunittorestore
thestoragevolume.