     Settings Password Protects Preset Modify:

     Used to prevent unauthorized use of the SYGS  
     for setting Presets and/or Channels. In the on  
     mode, the SYGS requires a Setup Password (see 
     Page 16 about setting Password) to access   
     Presets/Channels. In off mode, the SYGS allows  
     access to Presets and/or Channels while 
     maintaining password protection for Settings. 
     P: To initiate password protections, allow 
     the SYGS to cycle through its Timeouts.

Enable USB: 

The SYGS  is fitted with a Micro-B USB port for 
data access via a connecting cable. This allows you 
to update the unit’s firmware using your computer. 
For example, you can replace the Synergy Lighting 
Controls logo with a custom logo (see Page 31). 
Data corrections also can be made, if necessary. 

     Steps for updating the firmware:

     1.  Connect the SYGS to a computer using 
          a Micro-B USB cable.
     2.  After the computer recognizes the connection, 
          edit data file as needed.
     3.  When updates are completed, drag edited file 
          to the SYGS.
     4.  Before disconnecting the SYGS from your 
          computer, click “REMOVE HARDWARE 
          FROM COMPUTER” prompt, then disconnect.
     5.  Unplug the SYGS  to remove power.
     6.  Wait briefly for the data to update.

Summary of Contents for SYGS

Page 1: ...SYGS Operations Manual ...

Page 2: ......

Page 3: ...Synergy SYGS Graphical Control Station Operations Manual ...

Page 4: ......

Page 5: ...me Page Settings Timeouts Options Passwords Setup Access Colors Advanced Basic Operation Modifying Presets Adjusting and including excluding Channels Duplicating Channel settings Customization Options Adding a custom logo 5 7 11 11 13 of the SYGS 14 15 16 17 18 20 21 27 Operation 28 29 30 31 31 ...

Page 6: ...gramming check the firmware version Troubleshooting For Advanced Users SYGS Wiring The A4 Network Safety Information Customer Service Warranty 34 recall preset saved light levels modify present saved light levels adjust light levels identify the target locations identify the lights within a target location change target location labels check the firmware version determine target locations being co...

Page 7: ...hting attributes fade times levels of multiple targeted lighting groups called Presets or Scenes by adjusting multiple lighting circuits called Channels or Zones within each targeted group The SYGS Graphical Control Station you have purchased was engineered to provide years of reliable operation for commercial applications If assistance beyond the scope of this manual is required contact Synergy L...

Page 8: ...e Synergy Lighting Controls logo Fig 1 Slide your finger firmly across the bottom area of the screen to move to the Home Page of the SYGS Graphical Control Station Fig 2 NOTE A pen or other stylus like instrument will also work the SYGS is not temperature sensitive Fig 1 Swipe to unlock ...

Page 9: ... intensity for each of its selected Channels definition follows Channels Also identified as Zones Channels are groups of specific circuits of lights prescribed to each Preset according to common characteristics such as location or function Arrow buttons on the Channel screens raise or lower the intensity of the associated lights Fade Time Fade Time indicates how long it takes the lights to adjust ...

Page 10: ...logy Select SETTINGS then OPTIONS to get to the Options screen Fig 3 Toggle the KEYWORDS section using the or buttons until you get the combination you prefer The options are Presets Channels Presets Zones Scenes Channels Scenes Zones To save your selection tap the BACK button at the lower right then tap SAVE You will be returned to the SYGS Home Page Tap CANCEL to return to the Home Page without ...

Page 11: ...9 OVERVIEW OF THE SYGS ...

Page 12: ......

Page 13: ...off Preset Presets Presets are the preset light levels and fade times stored in the SYGS The PRESETS button on the SYGS Home Page Fig 2 changes the keypad view to the initial Presets control screen Fig 5 Each Presets screen provides four Presets at a time up to 16 Toggle through each set of four by using the NEXT or PREV buttons or by using the PAGE 1 button to return to the first set of Presets F...

Page 14: ... a Preset simply press the pre programmed button for the lighting scene you wish to activate Channels The CHANNELS button changes the keypad view to the Channels controls screen Fig 6 Each Channels screen provides four Channels at a time up to 32 Page through each set of four by using the NEXT or PREV buttons or by using the PAGE 1 button to return to the first page of Channels From Page 1 you can...

Page 15: ...utton changes the keypad view to the Settings control screen Fig 7 From this screen a wide variety of system preferences can be edited To save your selections be sure to tap the BACK button at the lower right and tap SAVE Fig 7 ...

Page 16: ...ttings you will be prompted to confirm this action Timeouts NOTE Timeouts on the SYGS screen are sequential Using the or buttons on the Timeouts screen Fig 8 select the amount of time 5 to 45 seconds 1 to 60 minutes for the SYGS to perform the following functions in order 1 Screen Automatically changes keypad view to Logo Page 2 Backlight Dim Automatically dims keypad s backlight once on Logo Page...

Page 17: ...e ability to adjust the brightness of the SYGS display Fig 3 Using the or buttons adjust the screen brightness level from 20 to 100 In addition the Options screen allows you to place an LED like indicator on each of the Preset buttons by placing an X in the blue box at the bottom left of the screen Indicator lights provide visual reference to each Preset status Fig 3 ...

Page 18: ...creen keyboards alpha or numeric 2 Toggle between the alpha and numeric keyboards Fig 11 using the lower right hand buttons on each screen 3 After entering your selected passwords tap the OK button to proceed or the CANCEL button to cancel the action 4 Tap the BACK button and SAVE your selection s NOTE Carefully record and keep your password in a secure location Reset of station will not clear use...

Page 19: ... to perform tasks specific to each security level The security levels are as follows User Password Locks out all functions presets channels modify presets settings Settings Password Locks out setting screen Optional lockout for Preset Modify function Admin Password Locks out ability to modify station address Locks out password screen ...

Page 20: ...es a moderate level of security by requiring users to swipe firmly with a finger across the bottom of the Logo screen to activate the SYGS In off mode the SYGS is activated by touching anywhere on the screen Timeout to Logo Screen Resets the SYGS to the Logo screen once the Timeout settings are reached In off mode no logo appears Home Page is Default Sets the Home Page as the screen default after ...

Page 21: ...a Micro B USB port for data access via a connecting cable This allows you to update the unit s firmware using your computer For example you can replace the Synergy Lighting Controls logo with a custom logo see Page 31 Data corrections also can be made if necessary Steps for updating the firmware 1 Connect the SYGS to a computer using a Micro B USB cable 2 After the computer recognizes the connecti...

Page 22: ... blue for the elements shown on the button in the center of the screen Use the PREV or NEXT buttons to toggle through Background Background text Preset normal Preset press Preset LED on Preset LED off Preset text Channel Bargraphs Button normal Button press Button text Button disabled Button disabled text The DEFAULT button returns the color schemes to the manufacturer s color settings Fig 13 ...

Page 23: ... screen Fig 15 provides information about the SYGS firmware Status The Status screen Fig 16 provides information about SYGS for up to 60 0 59 unique Addresses These listed Addresses refer to the available locations on the Synergy System A4 Network Use the NEXT or PREV buttons to toggle through the 60 Address locations to find information relevant to each SYGS device or tap the PAGE 1 button to ret...

Page 24: ... screens Accurate touching of the crosshairs resets the screen calibration accurately This function does not affect data Once calibration is completed the view is returned to the Logo screen NOTE If the calibration is set inaccurately allow the screen to time out to the Logo screen and or fade out Then press the screen firmly and continuously for 30 to 45 seconds to force a recalibration Fig 16 Fi...

Page 25: ...s up to 32 to be configured NOTE The Legacy Compatible prompt blue box must be marked with an X to allow control of the Presets and Channels for users with Legacy System hardware Legacy Systems can be defined as a Synergy Lighting Control System running controller firmware 2 65 or earlier To enable the use of the SYGS with a Legacy System select the Legacy Compatible prompt and choose the number o...

Page 26: ... the event that the eeprom becomes corrupt this will erase and reformat the eeprom All current settings will be saved back to the eeprom and any custom logo page will be erased Restore factory setting defaults Fig 19 This function restores basic factory settings to the SYGS but does not erase modified Preset Channel configurations or passwords Fig 18 Fig 19 ...

Page 27: ...25 BASIC OPERATION OF THE SYGS ...

Page 28: ......

Page 29: ...f LEDs are not enabled If a temporary modification is desired the or v arrow buttons will adjust the lighting level NOTE The method for modifying all Presets and Channels is the same Preset and Channel setting features must be saved to take effect After selecting setting preferences tap the BACK button at the lower right then tap SAVE You will be returned to the Presets control screen Tap CANCEL t...

Page 30: ...se the or buttons to the right of the Pre sets window to toggle to another Preset Or adjust the Fade Time setting by using the or buttons to the right of the Fade Time window This feature can be set from 0 seconds to 60 minutes and serves as a master light fading command for all Channels within each respective Preset IMPORTANT NOTE For Presets that have not yet been programmed the SYGS displays th...

Page 31: ...eferred light level 3 Once the Channels settings have been made tap the MODIFY button to return to the Presets controls screen and press SAVE to protect your new settings 4 To exclude specific Channels from the Preset you are programming tap the white window containing the name of the Channel so that it turns black with white lettering in colors default mode To exclude all Channels tap the EXC ALL...

Page 32: ...imilarly on the their Preset control screens 1 To easily duplicate Channel settings set the initial Preset to be duplicated 2 When viewing that Preset s Modify screen toggle to reach the number of the Preset you want to have the same settings using the or buttons 3 Once you reach the number of the Preset you re programming with the same Channel setting as the initial Preset hit the SAVE button 4 F...

Page 33: ...e SYGS to a computer using a Micro B USB cable 2 After the computer recognizes the connection to the SYGS navigate to the Synergy Lighting Controls Web site and click on the SUPPORT tab 3 From there click on the SYGS Logo Maker Setup wizard and double click on it to open 4 Follow the instructions in the wizard for installing the SYGS Logo Maker onto your computer 5 Use the wizard to replace the Sy...

Page 34: ...32 HOW DO I ...

Page 35: ......

Page 36: ...t light levels Move to the channels screen by pressing the Channels button Select the Channel you want to set modify by using the PREV or NEXT commands from the Channels control screen s Fig 23 Modify the Channels you want to set modify by toggling the or v arrow buttons to reach the preferred light level change button labels Preset and channel labels can be changed on the Stations tab in the SYSW...

Page 37: ...m that screen The text box above each channel indicates it function The text box below all the channels indicates the actual channel number restore factory default programming Under Advanced Fig 14 use the DEFAULTS button to restore basic factory settings to the SYGS This does not erase modified Preset Channel configurations ...

Page 38: ...LLOWED Using duplicate addresses will cause poor system performance erratic operation and network communication errors Check the following 1 Verify the A4 network address for each station 2 Verify the A4 network is terminated only at each end of the network 3 Verify the A4 network does not have any t taps The SYGS touchscreen is not responding when I touch it The screen calibration is not setup Al...

Page 39: ...ATE ADDRESSES ARE NOT ALLOWED The A4 Network The A4 network must be properly terminated for network operation The network device residing at each end of the network must be terminated The SYSC system controller is normally located at one end of the network and ships from the factory with termination activated Refer to SYGS installation instructions for termination instructions ...

Page 40: ...ment must be performed by qualified service personnel Synergy Lighting Controls a division of Acuity Brands Inc assumes no responsibility for claims arising out of improper or careless use or handling of this product Customer Service Contact Synergy Lighting Controls Technical Service at 800 533 2719 Synergy Lighting Controls Technical Service is available from 8 00 a m to 5 00 p m Monday to Frida...

Page 41: ...tion and operation for a period of three 3 years Our guarantee liability extends only to the repair or replacement of the defective part and no labor charges for correction of the defect by repair or replacement will be honored by Synergy Lighting Controls unless prior written authorization has been granted by our Customer Service Department ...

Page 42: ... 2011 Acuity Brands Lighting Inc All Rights Reserved 10 11 Part No TS SYGS 002 ...

Reviews: