![Symmetricom XL-GPS User Manual Download Page 112](http://html.mh-extra.com/html/symmetricom/xl-gps/xl-gps_user-manual_1419609112.webp)
5: Function Reference
Locked: The DAC, which disciplines the clock oscillator to the reference source, is operating
nominally.
Unlocked: The DAC is operating out of specifications. Return to Symmetricom for service.
See
“H: Sales and Customer Assistance” on page 204
.
1st Time Lock
Time Error and Time Threshold
Time Error issues an alarm when the worst case time error (
“F13 – Time Error” on page 67
)
of the XL-GPS system clock exceeds the user-set Time Threshold.
Note: With Time Threshold set to zero, the unit applies a default value of 150 nS.
LED Blink
When LED Blink is enabled, the Alarm Status LED on the front panel blinks when it is green
or amber. The LED does not blink when it is red, even if LED Blink is enabled. Some users
disable LED Blink to ensure that the LED’s color (state) is displayed without interruption.
Timeout and Timeout Delay
Timeout and Timeout Delay can be used to prevent short-term Time Error faults from
triggering Time Error alarms.
Timeout Disabled: All Time Error faults trigger an alarm, regardless of duration.
Timeout Enabled: Only Time Error faults that last longer than the Timeout Delay (measured
in seconds) trigger an alarm. If a Time Error fault clears and returns to an OK state before the
Timeout Delay has elapsed, the ‘countdown’ stops and no alarms are triggered. All Time
Error faults start the Timeout Delay ‘countdown’ from the beginning (i.e., Timeout Delay
does not keep a countdown tally for multiple Time Error faults).
Power On Alarm Suppress
Power On Alarm Suppress prevents all F73 alarms from occurring for a specified interval
after the unit starts up. The factory default setting is 300 seconds (five minutes). When that
interval ends, current and new alarms are reported normally.
NTP
OK: NTS is operating nominally.
Fault: NTS is not operating correctly. Contact Symmetricom Customer service. See
“H:
Sales and Customer Assistance” on page 204
.
Clear Alarm Latch
Page 98 of 221
.................................
098-00116-000 Rev. A
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...