F67 – Manual Leap Seconds Entry/Request
F67 – Manual Leap Seconds Entry/Request
Use Serial/Network Function F67 to manually enable a leap second insertion into the XL-
GPS clock time structure. To request the present status of the manual leap seconds settings,
send F67<CR> to the Serial/Network port. The port will respond with the ASCII character
string:
F67<SP><LS><SP><SELECT><SP><DATE><CR><LF>
where:
F = ASCII character F.
67 = function number
<SP> = ASCII space character one or more.
<LS> = current leap seconds value in seconds, for GPS Epoch / TAI Epoch
<SELECT> = NONE, ADD or SUB.
<DATE> = Date of next leap second insertion, or blank if <SELECT> is NONE.
<CR> = carriage return character.
<LF> = line feed character.
If the Manual Leap Second function is set with leap second event values, the port will
respond with the string described below.
Sample request: F67 <CR>
Response: F67 -14/-33 ADD 12/31/2007 <CR><LF>
To set the current leap second value for UTC / GPS , enter a continuous string of the form:
F67 <SP>GPSLS<SEP><-nn>
where:
GPSLS = ASCII string indicating a GPS Epoch leap second value will be entered.
<-nn> = Leap second valued entered, -00 to –30.
Sample entry: F67 GPSLS -14<CR>
Response: OK<CR><LF>
To set the current leap second value for UTC / TAI , enter a continuous string of the form:
098-00116-000 Rev. A
...............................
Page 87 of 221
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...