DOC06501_Revision
F
ATS-6501 Users Guide
74
[external] locked
10Mhz Ref Status
[internal] locked
Internal RB Locked to reference.
[lns] locked
Low Noise Synth(Unlocked/Locked)
[locked] true
System Locked (true/false)
[outputs] enabled
Outputs (Enabled/Disabled)
[temperature] 31
System Temperature (C)
[tflex]
Unit
Information
[network]
Current Network Settings
[MAC] 00:30:96:00:00:98
Unit MAC Address
[broadcast] 192.168.1.255
Current Broadcast Address
[default_gateway] 192.168.1.1
Current Default Gateway Address
[ip] 192.168.1.253
Current IP Address
[netmask] 255.255.255.0
Current Netmask
[serial_number] SP00220
Serial Number
[start] 2008-10-02-17:49
Date/Time of last restart
[uptime] 2 hours, 2 minutes, 54 seconds
Total time systems been up
[ver] 3.4.2
Software version
[time] 2009-10-02-19:52:03
Time status data requested
System Errors:
Alarms and events on the ATS-6501 are available via the
status
command. As
the events occur the system will
set
the alarm and time. Once the condition clears the system will
indicate the condition
cleared
, what the condition was, when it cleared and increment the
occurrence counter.
[clock_wander]
[active] false
[cleared]
[what] Clock wander is less than 100.000000ns
[when] 2009-01-26-22:18:48.141
[occurrences] 1
[set]
[what] Clock wander exceeded 100.000000ns
[when] 2009-01-26-22:18:35.922