SYMEO Local Positioning Radar System
LPR-1DHP
Product Documentation
Mounting
Copyright © Symeo GmbH 2012
Page 17 of 40
5
Mounting
When the system is mounted on fixed tubes the necessary
measures to prevent slippage of the system must be taken
All installation, repair and servicing work must be carried out by
qualified and trained technicians!
A lot of the terms used in the following description are explained in
Figure 1 and Figure 3.
The LPR-1DHP station (front and rear element) is delivered pre-mounted, and with a
separate mounting bracket. Figure 1 shows the complete system including mounting bracket.
The mounting bracket must be mounted with a separte pipe clamp on a pipe. For mounting
the system please proceed as follows:
Please use a torx wrench type T25 to remove the front element A from the rear element
B by loosening of the mounting screws (A2). If necessary you can disconnect the
ethernet cable (B5) from the front element (A3) to be more flexible.
Insert the power supply cable in the cable feedthrough (B3) and connect it to the power
supply terminal (A4) on the rear element (A); siehe Figure 6.
Reinsert the Ethernet connector (B5) of the rear element (B) into the connector (A3) of
front element (A). Mount the front element (A) on the rear element (B). It might be
necessary to tighten the inserted power cable.
Fix the front element on the rear element with the housing screws (A2) using a torx
wrench T25.
Carefully tighten the cable feedthrough with flat wrench SW19.
Mount the mounting bracket (C) on a pipe installed at a suitable place. Do not tighten the
screws of the pipe-clamp yet, the system must be aligned first.
Mount the LPR-1DHP station in the mounting bracket (C). When tightening the screws in
the mounting slot (C1) make sure that you can still align the system unit.
Carefully align both units. To do so, it is recommended to use a laser level fitted into the
alignment aid (B1).
Finally fix the system by tightening the screws of the mounting bracket and the pipe
clamp. Flat wrench SW 11 and 13 are required.
Avoid entry of foreign objects or liquids into the system unit,
especially on the PCB stack of front element (A) or within rear
element (B).
It is important that both units have the same orientation, e.g. the
display of both units facing the ceiling.
Careful mounting of the system is required. It is important that the
joint (A6) remains clean and is not damaged, otherwise the
protection class cannot be guaranteed.