Serial Port Parameter
Setting
Baud rate
38400
Data Bits
8
Stop Bits
1
Parity
No
Handshake
No
Please select the serial port number assigned by the system to the controller,then
click ”Open” button in Fig2.2 to connect controller and enumerate all axes attached to this
controller at the same time; The button name will change from “Open” to “Close” and the status
area will display:”COM7:Open Success”,Axis field will list all axes enumerated if connection is
successful;otherwise status area will display ”COM7:Open Fail”.
Fig 2. 2 connect
Fig 2. 3 connect success
2.3 Status
“Connection phase” Display the connection status such as:Begin to Scan Axis ......, and the
number of axes enumerated, etc.
“Motion phase” Display whether reach the position of positive or negative soft limit or not.
2.4 Motion Parameters
“
Move Mode
”
This field indicates the moving mode.Normal set low resolution
,
high
resolution can move in nanometer scale
“Vel” This field indicates the controllers current set value for velocity
“Accel” This field indicates the controllers current set value for acceleration
“Decel” This field indicates the controllers current set value for acceleration
2.5 Open Or Closed Loop
“Loop” This field allows you to choose 3 different modes of motion