www.symc-tec.com
The Chapter Two Software Operation Instruction
11
“+Travel Limit” - The soft travel limit in the positive direction
“StepRes” - Steps per micron resolution
“EncRes” - Microns per encoder count
2.9 Polarity Settings
“Encoder Polarity” field allows you to flip positive and negative directions of the Encoder
:
“Default” This is the default encoder polarity
“Reverse” This selection reverse encoder polarity,select this option
only if the direction of motion contrary to the direction of feedback
“Motor Polarity” field allows you to flip positive and negative directions of the Motor
:
“Default” This is the default motor polarity,the positive direction is away from motor
;
“Reverse” This selection will reverse motor polarity,the positive direction is toward
motor
;
2.10 Test
“Max Position” – Set this value to the desired upper limit of travel
“Min Position” - Set this value to the desired lower limit of travel
“Start” This will execute the movements between limits
“Position” This column is position number of motion
“Dest” This column is the destination position for the move that is currently
occurring.
“Time” This column indicates the time at which each move arrived.
2.11 Menu
“Settings” item allows you to handle current axis settings:
“Save Current Axis Parameters to Flash” This sub-item can save current axis settings to
FLASH;
“Save Current Axis Parameters to File” This sub-item can save current axis settings to
File;
“Read Current Axis Parameters from File” This sub-item can load current axis settings
from File ;
“
Axis Address Setting
”
This sub-item can set axis address
、
change current axis address
and set auto configured axis address
;
“
System Other Parameters Setting
”
This sub-item can open “System” setting view.