5-50
LS 4000P Series Product Reference Guide
Buffer Data
To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space
immediately following the start pattern.
!
Unless symbol overflows the transmission buffer, the scanner issues a lo/hi beep to
indicate successful decode and buffering. See Overfilling Transmission Buffer.
!
The scanner adds the message, excluding the leading space to the transmission buffer.
!
No transmission occurs.
Clear Transmission Buffer
To clear the transmission buffer, scan the following symbol, which contains only a start
character, a dash (minus), and a stop character.
!
The scanner issues a short hi/lo/hi beep to signal that the transmission buffer has
been erased, and no transmission has occurred.
!
The scanner erases the transmission buffer.
!
No transmission occurs.