A-5
Programming Reference
Code 93
0
No options specified at this time. Always transmit 0.
Example:
A Code 93 bar code 012345678905 is transmitted as
]G0012345678905
MSI Plessey
0
Single check digit checked.
1
Two check digits checked.
2
Single check digit verified and stripped before
transmission.
3
Two check digits verified and stripped before
transmission.
Example:
An MSI Plessey bar code 4123, with a single check digit checked,
is transmitted as ]M04123
D 2 of 5
0
No options specified at this time. Always transmit 0.
Example:
A D 2 of 5 bar code 4123, is transmitted as ]S04123
UPC/EAN
0
Standard packet in full EAN country code format, which
is 13 digits for UPC-A and UPC-E (not including
supplemental data).
1
Two-digit supplement data only.
2
Five-digit supplement data only.
4
EAN-8 data packet.
Example:
A UPC-A bar code 012345678905 is transmitted as
]E00012345678905
Bookland EAN
0
No options specified at this time. Always transmit 0.
Example:
A Bookland EAN bar code 123456789X is transmitted as
]X0123456789X
Table A-3. Modifier Characters (Continued)
Code Type
Option Value
Option
Summary of Contents for LS4000P Series
Page 1: ...LS 4000P Series Product Reference Guide...
Page 3: ...LS 4000P Series Product Reference Guide 70 37631 01 Revision B November 2000...
Page 10: ...viii LS 4000P Series Product Reference Guide...
Page 18: ...1 2 LS 4000P Series Product Reference Guide...
Page 40: ...4 10 LS 4000P Series Product Reference Guide...
Page 151: ...5 111 Parameter Menus Numeric Bar Codes Continued 5 6 7 8 9...
Page 158: ...A 6 LS 4000P Series Product Reference Guide...
Page 168: ...Index 4 LS 4000P Series Product Reference Guide...
Page 170: ......