5-88
LS 4071 Product Reference Guide
RS-232C Parameters
Hardware Handshaking
When Option 2 is selected, RTS is always high or low (user-programmed logic
level). However, the base waits for CTS to be asserted before transmitting data.
If CTS is not asserted within two seconds (default), the base issues an error
indication and discards the data.
RTS/CTS OPTION 2
When Option 3 is selected, the base asserts RTS prior to any data transmission,
regardless of the state of CTS. The base waits up to two seconds (default) for
CTS to be asserted. If CTS is not asserted during this time, the base issues an
error indication and discards the data. The base deasserts RTS when
transmission is complete.
RTS/CTS OPTION 3
Summary of Contents for LS 4071
Page 1: ...LS 4071 Product Reference Guide...
Page 3: ...LS 4071 Product Reference Guide 70 19303 02 Revision A December 1999...
Page 8: ...vi Appendix A UCC EAN 128 A 2 AIM Code Identifiers A 4 Appendix B Glossary Index...
Page 14: ...xii LS 4071 Product Reference Guide...
Page 18: ...1 4 LS 4071 Product Reference Guide...
Page 26: ...2 8 LS 4071 Product Reference Guide...
Page 143: ...5 99 Parameter Menus Numeric Bar Codes Cont d 4 5 6 7...